The Alzheimer's Disease Neuroimaging Initiative (ADNI) is a longitudinal multisite observational study of healthy elders, mild cognitive impairment (MCI), and Alzheimer's disease. Magnetic resonance imaging (MRI), (18F)-fluorodeoxyglucose positron emission tomography (FDG PET), urine serum, and cerebrospinal fluid (CSF) biomarkers, as well as clinical/psychometric assessments are acquired at multiple time points. All data will be cross-linked and made available to the general scientific community. The purpose of this report is to describe the MRI methods employed in ADNI. The ADNI MRI core established specifications that guided protocol development. A major effort was devoted to evaluating 3D T(1)-weighted sequences for morphometric analyses. Several options for this sequence were optimized for the relevant manufacturer platforms and then compared in a reduced-scale clinical trial. The protocol selected for the ADNI study includes: back-to-back 3D magnetization prepared rapid gradient echo (MP-RAGE) scans; B(1)-calibration scans when applicable; and an axial proton density-T(2) dual contrast (i.e., echo) fast spin echo/turbo spin echo (FSE/TSE) for pathology detection. ADNI MRI methods seek to maximize scientific utility while minimizing the burden placed on participants. The approach taken in ADNI to standardization across sites and platforms of the MRI protocol, postacquisition corrections, and phantom-based monitoring of all scanners could be used as a model for other multisite trials.
What this study adds
Evidence grade: Moderate
This is a follow-up (cohort) study. This report describes the MRI methods used in the Alzheimer's Disease Neuroimaging Initiative, a longitudinal multisite observational study of healthy elders, mild cognitive impairment, and Alzheimer's disease. The protocol selected includes back-to-back 3D MP-RAGE scans, B1-calibration scans when applicable, and an axial proton density-T2 dual contrast scan for pathology detection, with data made available to the general scientific community.
Taken from this record’s own fields, not from reading the paper. The grade is assigned from the abstract’s wording; what that means.
Cite this study APA, Vancouver, BibTeX · download .bib or .ris
APA 7th
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P. M., Alexander, G. E., Harvey, D. J., et al. (2008). The Alzheimer's disease neuroimaging initiative (ADNI): MRI methods. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21049
Vancouver
Jack CR, Bernstein MA, Fox NC, Thompson PM, Alexander GE, Harvey DJ, et al. The Alzheimer's disease neuroimaging initiative (ADNI): MRI methods. Journal of Magnetic Resonance Imaging. 2008. doi:10.1002/jmri.21049. PMID: 18302232.
BibTeX
@article{jack2008-18302232,
author = {Jack, Clifford R. and Bernstein, Matt A. and Fox, Nick C. and Thompson, Paul M. and Alexander, Gene E. and Harvey, Danielle Jenine and Borowski, Bret and Britson, Paula J. and others},
title = {{The Alzheimer's disease neuroimaging initiative (ADNI): MRI methods}},
journal = {Journal of Magnetic Resonance Imaging},
year = {2008},
doi = {10.1002/jmri.21049},
pmid = {18302232},
url = {https://doi.org/10.1002/jmri.21049}
}
Built from the record alzhub holds for this paper, not looked up. Volume, issue and page numbers are not held in the record. The record's author list ends in “et al.”, so not every author is named. Check the citation against the original before you use it.
Key findings
- A major effort was devoted to evaluating 3D T(1)-weighted sequences for morphometric analyses.
- Several options for this sequence were optimized for the relevant manufacturer platforms and then compared in a reduced-scale clinical trial.
- The protocol selected for the ADNI study includes: back-to-back 3D magnetization prepared rapid gradient echo (MP-RAGE) scans; B(1)-calibration scans when applicable; and an axial proton density-T(2) dual contrast (i.e., echo) fast spin echo/turbo spin echo (FSE/TSE) for pathology detection.
- ADNI MRI methods seek to maximize scientific utility while minimizing the burden placed on participants.
- The approach taken in ADNI to standardization across sites and platforms of the MRI protocol, postacquisition corrections, and phantom-based monitoring of all scanners could be used as a model for other multisite trials.
Why it matters
This report describes the MRI methods used in the Alzheimer's Disease Neuroimaging Initiative, a longitudinal multisite observational study of healthy elders, mild cognitive impairment, and Alzheimer's disease. The protocol selected includes back-to-back 3D MP-RAGE scans, B1-calibration scans when applicable, and an axial proton density-T2 dual contrast scan for pathology detection, with data made available to the general scientific community.
New to this subject? Start with our plain-English guide: Brain scans & tests →
Study details
- Study designlongitudinal study
- Evidence strengthModerate
How this study scored 72/100
Published in a peer-reviewed journal, and it is a longitudinal study following the same people over time. Scored zero for sample size, effect reported, studied in people and randomized / blinded because the record does not state it.
| Component | Points | Why |
|---|---|---|
| Journal tier | 7 / 10 | Tier 3 — peer-reviewed journal (Journal of Magnetic Resonance Imaging) |
| Journal's citation record | 2 / 4 | Journal of Magnetic Resonance Imaging: journal h-index 217 (OpenAlex, 2026-10-29) |
| Study design | 7 / 12 | A longitudinal study following the same people over time |
| Strength of evidence | 3 / 5 | Rated “moderate” in our summary |
| Peer-review validation | 10 / 10 | Peer-reviewed. Published as an article in a named peer-reviewed journal. |
| How recent | 1 / 5 | 2008 — within 20 year(s) of the newest study here |
| Sample size | 0 / 4 | Participant count not stated — scores zero (not stated in the record — scored 0) |
| Effect reported | 0 / 3 | No effect size reported — scores zero (not stated in the record — scored 0) |
| Studied in people | 0 / 3 | Not stated whether this was studied in people — scores zero (not stated in the record — scored 0) |
| Randomized / blinded | 0 / 2 | No randomization or blinding stated — scores zero (not stated in the record — scored 0) |
| Times cited | 7 / 7 | Cited 4,375 times (OpenAlex, 2026-10-10) |
| Citations per year | 5 / 5 | 218.8 citations a year over 20 year(s) since 2008 |
| Impact for its field and year | 6 / 6 | Cited 78.3× the average for papers of its field and year (OpenAlex FWCI) |
| Cited by studies here | 6 / 6 | Cited by 201 other studies in this library |
| Still being cited | 4 / 4 | Cited 941 times in 2024–2026 (2026 still in progress; OpenAlex) |
| Senior author's track record | 4 / 4 | Last-listed author Michael Walter Weiner: h-index 171 (OpenAlex, whole career) |
| Institution's track record | 3 / 3 | Stanford University: institution h-index 2,684 (OpenAlex) |
| Multicenter collaboration | 3 / 3 | OpenAlex lists 18 institution(s) in 3 countries |
| Indexed in PubMed | 2 / 2 | Indexed in PubMed (PMID 18302232) |
| Free to read | 2 / 2 | Free to read |
| Total | 72 / 100 | — |
What each of these 20 components measures, and what this score is not →
Read the original
- DOI: 10.1002/jmri.21049
- PubMed: 18302232
- Original source →
- Free full text: Journal of Magnetic Resonance Imaging →
Full text: free to read — OpenAlex lists this copy as free to read: the link above (checked 6 Feb 1020).
Related
Studies in the library that share something with this one. The line above each title says what.
Studies this one cites
Referenced by this study and also in the alzhub library, so you can read them here.
Later studies that cite this one
201 studies in the alzhub library list this one in their references. Showing the 8 highest-scoring.
Related studies in Brain scans and imaging from nearby years
Also tagged “machine”
834 studies in the library carry the topic tag “machine”; these are this study's neighbours in a fixed, alphabetical-by-hash tour of them, not the closest in content. All 834 tagged studies.