Home › Research › Digital health tools
Cerebral microbleed detection using Susceptibility Weighted Imaging and deep learning
Liu S, Utriainen D, Chai C, Chen Y, Wang L, Sethi SK, Xia S, Haacke EM.. NeuroImage, 2019-05-20
Topic: Risk, prevention and care in population studies
Plain-language summary
Detecting cerebral microbleeds (CMBs) is important in diagnosing a variety of diseases including dementia, stroke and traumatic brain injury. However, manual detection of CMBs can be time-consuming and prone to errors, whereas the current automatic algorithms for CMB detection are usually limited by large number of false positives. In this study, we present a two-stage CMB detection framework which contains a candidate detection stage based on a 3D fast radial symmetry transform of the composite images from Susceptibility Weighted Imaging (SWI), and a false positive reduction stage based on deep residual neural networks using both the SWI and the high-pass filtered phase images. While the SWI images provide exquisite sensitivity to the presence of blood products, the high-pass filtered phase images enable the differentiation of diamagnetic calcifications from paramagnetic microbleeds. The deep learning model was trained using 154 data sets, and the best models were selected using 25 validation data sets. Finally, the models were tested using 41 cases, including 13 hemodialysis cases, 9 traumatic brain injury cases, 9 stroke cases and 10 healthy controls. Using 3D SWI and high-pass filtered phase images as input, the best model led to a sensitivity of 95.8%, a precision of 70.9%, and 1.6 false positives per case. This model achieved similar performance to the most experienced human rater and outperformed recently reported CMB detection methods. This study demonstrates the potential of applying deep learning techniques to medical imaging for improving efficiency and accuracy in diagnosis.
Cite this study APA, Vancouver, BibTeX · download .bib or .ris
APA 7th
Liu, S., Utriainen, D., Chai, C., Chen, Y., Wang, L., Sethi, S. K., et al. (2019). Cerebral microbleed detection using Susceptibility Weighted Imaging and deep learning. NeuroImage. https://doi.org/10.1016/j.neuroimage.2019.05.046
Vancouver
Liu S, Utriainen D, Chai C, Chen Y, Wang L, Sethi SK, et al. Cerebral microbleed detection using Susceptibility Weighted Imaging and deep learning. NeuroImage. 2019. doi:10.1016/j.neuroimage.2019.05.046. PMID: 31121296.
BibTeX
@article{liu2019-31121296,
author = {Liu, S. and Utriainen, D. and Chai, C. and Chen, Y. and Wang, L. and Sethi, S. K. and Xia, S. and Haacke, E. M.},
title = {{Cerebral microbleed detection using Susceptibility Weighted Imaging and deep learning}},
journal = {NeuroImage},
year = {2019},
doi = {10.1016/j.neuroimage.2019.05.046},
pmid = {31121296},
url = {https://doi.org/10.1016/j.neuroimage.2019.05.046}
}
Built from the record alzhub holds for this paper, not looked up. Volume, issue and page numbers are not held in the record. The record names 8 authors; APA and Vancouver show the first six, BibTeX and the downloads carry all of them. Check the citation against the original before you use it.
Key findings
- The deep learning model was trained using 154 data sets, and the best models were selected using 25 validation data sets.
- Finally, the models were tested using 41 cases, including 13 hemodialysis cases, 9 traumatic brain injury cases, 9 stroke cases and 10 healthy controls.
- Using 3D SWI and high-pass filtered phase images as input, the best model led to a sensitivity of 95.8%, a precision of 70.9%, and 1.6 false positives per case.
- This model achieved similar performance to the most experienced human rater and outperformed recently reported CMB detection methods.
- This study demonstrates the potential of applying deep learning techniques to medical imaging for improving efficiency and accuracy in diagnosis.
New to this subject? Start with our plain-English guide: Digital health →
Study details
- Effect size95.8%; 70.9%
- Evidence strengthLow
How this study scored 41/100
Published in a peer-reviewed journal. Scored zero for study design, sample size, studied in people and randomized / blinded because the record does not state it. We have no data on journal's citation record, times cited, citations per year, impact for its field and year, cited by studies here, still being cited, senior author's track record, institution's track record and multicenter collaboration, so those were left out: it earned 24 of the 58 points we could judge it on, which is 41 out of 100.
| Component | Points | Why |
|---|---|---|
| Journal tier | 7 / 10 | Tier 3 — peer-reviewed journal (NeuroImage) |
| Journal's citation record | — / 4 | No journal record from OpenAlex — left out of this score |
| Study design | 0 / 12 | No study design recorded — scores zero, not guessed (not stated in the record — scored 0) |
| Strength of evidence | 1 / 5 | Rated “low” in our summary |
| Peer-review validation | 10 / 10 | Peer-reviewed. Published as an article in a named peer-reviewed journal. |
| How recent | 2 / 5 | 2019 — within 10 year(s) of the newest study here |
| Sample size | 0 / 4 | Participant count not stated — scores zero (not stated in the record — scored 0) |
| Effect reported | 2 / 3 | Effect reported as a number, without an interval or test |
| Studied in people | 0 / 3 | Not stated whether this was studied in people — scores zero (not stated in the record — scored 0) |
| Randomized / blinded | 0 / 2 | No randomization or blinding stated — scores zero (not stated in the record — scored 0) |
| Times cited | — / 7 | No citation count (not found in OpenAlex) — left out of this score |
| Citations per year | — / 5 | No citation count or no year — left out of this score |
| Impact for its field and year | — / 6 | No field-weighted citation impact (OpenAlex has none yet) — left out of this score |
| Cited by studies here | — / 6 | Not yet checked against this library's citation graph — left out of this score |
| Still being cited | — / 4 | No yearly citation counts — left out of this score |
| Senior author's track record | — / 4 | Senior author's record not available — left out of this score |
| Institution's track record | — / 3 | No institution listed in OpenAlex — left out of this score |
| Multicenter collaboration | — / 3 | Institutions not listed — left out of this score |
| Indexed in PubMed | 2 / 2 | Indexed in PubMed (PMID 31121296) |
| Free to read | 0 / 2 | Behind a paywall — scores zero |
| Points | 24 / 58 | Scored on 11 of 20 parts. We have no data for the rest, so they are left out: 24 of the 58 points we could judge it on is 41 out of 100. |
| Total | 41 / 100 | — |
What each of these 20 components measures, and what this score is not →
Read the original
Free copy unknown: no free-copy check has an answer for this record yet. That does not mean it is paywalled.
Related
Studies in the library that share something with this one. The line above each title says what.
Related studies in Digital health tools from nearby years
Also tagged “weighted”
3 studies in the library carry the topic tag “weighted”; these are this study's neighbours in a fixed, alphabetical-by-hash tour of them, not the closest in content. All 3 tagged studies.