Cognivue Clarity / Cognivue Thrive
Measured
FDA-cleared
- Made by Cognivue, Inc. (originally Cerebral Assessment Systems, Inc.)
- Cleared 2015-06-05
- Reimbursement: Not verified from a loaded page (see CMS CPT 96146 item for the generic Medicare payment for automated computerized testing). Generic Medicare context (measured, CMS Physician & Other Practitioners by Geography and Service, 2024 data, national): CPT 96146 (automated single-instrument electronic test administration) avg Medicare allowed $2.23 office / $2.14 facility, 8,782 office services to 4,470 beneficiaries by 207 providers; CPT 99483 (cognitive assessment & care plan) avg allowed $255.96 office / $180.23 facility, 130,107 office services to 117,441 beneficiaries; CPT 96136 (test administration first 30 min) avg allowed $39.87 office; CPT 96132 (neuropsych evaluation first hour) $124.09 office. No product-specific code; vendor reimbursement claims not verified.
- What it is for
- Computerized cognitive assessment aid (FDA product code PKQ, 21 CFR 882.1470) granted via De Novo DEN130033; 10-minute self-administered visuomotor test for adults 55-95 at risk of age-related cognitive decline. Later Clarity/Thrive models are listed under the 510(k)-exempt code PTY (openFDA registration listing, created 2020-03-04).
- Who it was tested in
- Adults 55-95 at outpatient clinics and assisted/independent-living facilities (cut-off study n=92; clinical validation n=401, of whom 358 completed two sessions) [Cahn-Hidalgo 2020, World J Psychiatry]. Bio-Hermes cohort n=887 with amyloid PET (388 cognitively normal, 282 MCI, 217 probable AD) [2024, Sci Rep].
- Published accuracy
- Vs SLUMS reference (2020): weighted kappa 0.57 (95% CI 0.50-0.63); test-retest r=0.90; scores <=50 classified impaired, >=75 unimpaired. Bio-Hermes (2024, n=887): positive likelihood ratio 2.17, negative likelihood ratio 0.29, diagnostic odds ratio 7.48 for biomarker-confirmed MCI-AD/AD vs true controls; Cohen d 0.732 impaired vs normal. CARM amyloid measure (2025): OR 3.67 (95% CI 2.76-4.89) for amyloid-PET positivity (derived in the same cohort, not externally validated). Independent psychiatric-outpatient comparison (2021, n=58): only 43% agreement with MoCA; authors advised caution.
- Strength of evidence
- Moderate: one manufacturer-run validation (2020) and one large biomarker-confirmed cross-sectional cohort (Bio-Hermes, 2024, industry-sponsored consortium). No sensitivity/specificity vs clinical diagnosis reported in abstracts; independent small study found poor MoCA agreement. Not validated for longitudinal progression.
Regulatory: openFDA device/510k record DEN130033 (decision 2015-06-05, product code PKQ, direct De Novo). Evidence: PMID 31956523 (doi 10.5498/wjp.v10.i1.1, 2020); PMID 39424626 (doi 10.1038/s41598-024-75304-5, 2024); PMID 40192926 (doi 10.1007/s40120-025-00741-x, 2025); PMID 34327120 (doi 10.5498/wjp.v11.i7.265, 2021 critique). Marketed claims beyond these (e.g., 'amyloid risk') rest on CARM derivation within Bio-Hermes only.
Source: accessdata.fda.gov
CANTAB Mobile / CANTAB Paired Associates Learning (PAL)
Measured
FDA-cleared
- Made by Cambridge Cognition Ltd
- Cleared 2017-01-13
- Reimbursement: Generic Medicare context (measured, CMS Physician & Other Practitioners by Geography and Service, 2024 data, national): CPT 96146 (automated single-instrument electronic test administration) avg Medicare allowed $2.23 office / $2.14 facility, 8,782 office services to 4,470 beneficiaries by 207 providers; CPT 99483 (cognitive assessment & care plan) avg allowed $255.96 office / $180.23 facility, 130,107 office services to 117,441 beneficiaries; CPT 96136 (test administration first 30 min) avg allowed $39.87 office; CPT 96132 (neuropsych evaluation first hour) $124.09 office. No product-specific code; vendor reimbursement claims not verified.
- What it is for
- 510(k) K161328 (product code PKQ, Computerized Cognitive Assessment Aid), iPad-based PAL test for memory impairment in older adults, intended as aid to clinical assessment (openFDA 510k record).
- Who it was tested in
- PAL has a 30-year literature in healthy volunteers, MCI and AD (review 2016). Recent diagnostic-accuracy study: 65 participants with MoCA-defined MCI (15/65) [2026, Acta Psychologica].
- Published accuracy
- PAL mean-errors-to-success AUC 0.80 (95% CI 0.66-0.95) for MoCA-defined MCI, cut-off 5.8: sensitivity 77%, specificity 74% (2026, n=65, small sample, MoCA as reference not clinical diagnosis).
- Strength of evidence
- Moderate for construct validity (extensive PAL literature incl. fMRI hippocampal studies); weak for the specific CANTAB Mobile product as a screening tool (small diagnostic-accuracy samples; reference standard often another screener).
Regulatory: openFDA device/510k K161328, decision 2017-01-13, applicant Cambridge Cognition Ltd. Evidence: PMID 42567065 (doi 10.1016/j.actpsy.2026.107597, 2026); PMID 27646012 (doi 10.1007/7854_2015_5001, 2016 review); PMID 21477602 (2011 fMRI MCI). Widely used in trials (research-use platform) separate from the cleared clinical product.
Source: accessdata.fda.gov
Linus Health DCTclock / Digital Clock and Recall (DCR)
Measured
FDA-cleared
- Made by Linus Health, Inc. (DCTclock originally Digital Cognition Technologies)
- Reimbursement: Generic Medicare context (measured, CMS Physician & Other Practitioners by Geography and Service, 2024 data, national): CPT 96146 (automated single-instrument electronic test administration) avg Medicare allowed $2.23 office / $2.14 facility, 8,782 office services to 4,470 beneficiaries by 207 providers; CPT 99483 (cognitive assessment & care plan) avg allowed $255.96 office / $180.23 facility, 130,107 office services to 117,441 beneficiaries; CPT 96136 (test administration first 30 min) avg allowed $39.87 office; CPT 96132 (neuropsych evaluation first hour) $124.09 office. No product-specific code; vendor reimbursement claims not verified.
- What it is for
- FDA-listed Class II 510(k)-exempt Computerized Cognitive Assessment Aid (product code PTY, 21 CFR 882.1470); openFDA registration listing 'Linus Health Platform'/'Linus Health Clinical Platform', listing created 2017-12-22, registration valid through 2026. Digitized clock-drawing analysed with machine learning; DCR adds a word-recall task. Note: 'FDA-listed/exempt' is not a reviewed clearance; no 510(k) number exists.
- Who it was tested in
- DCTclock: 300 participants from Harvard Aging Brain Study / MGH PET lab (264 clinically normal, 143 with amyloid+tau PET; 36 MCI/early AD) [Rentz 2021, Neurology, Class II evidence]. DCR: Bio-Hermes-001 n=945 with external validation in Apheleia cohort n=238 [2026, Front Digit Health]. Framingham Heart Study dCDT: 87 low-age-risk adults with amyloid/tau PET [2025, Sci Rep].
- Published accuracy
- DCTclock AUC 0.86 for MCI/early AD vs clinically normal (n=300); among clinically normal, summary score discriminated amyloid+/- with Cohen d 0.76 vs 0.30 for PACC (2021). Framingham dCDT composite + demographics: mean AUC 0.86 for amyloid positivity (n=87, 2025, internal cross-validation). DCR-to-MMSE crosswalk model: RMSE 2.43 in held-out Bio-Hermes test set and 2.62 in external Apheleia cohort (2026) - this is one of the few digital tools with a reported external validation cohort.
- Strength of evidence
- Moderate-to-strong for association with amyloid/tau PET and diagnostic discrimination in research cohorts; company-affiliated authorship on DCR papers; primary-care performance vs MoCA reported (JGIM 2026, correction noted) but abstract not we hold.
REGULATORY NUANCE: this product is FDA-LISTED as a 510(k)-EXEMPT Class II device (product code PTY, 21 CFR 882.1470) - it has had NO FDA premarket review and has no K-number; it is coded 'FDA-cleared' only because the schema offers no 'FDA-listed/exempt' value. Vendor phrases such as 'FDA Class II' or 'FDA-registered' refer to this listing. Regulatory: openFDA device/registrationlisting, registration name 'Linus Health, Inc.', product code PTY, exempt. Evidence: PMID 33589537 (doi 10.1212/wnl.0000000000011697, 2021); PMID 42495050 (doi 10.3389/fdgth.2026.1799372, 2026); PMID 40169870 (doi 10.1038/s41598-025-95852-8, 2025); PMID 39533697 (2024, DCR vs FAQ functional impairment, no numbers in abstract).
Source: doi.org
BrainCheck Assess
Measured
FDA-cleared
- Made by BrainCheck, Inc. (Austin, TX)
- Reimbursement: Generic Medicare context (measured, CMS Physician & Other Practitioners by Geography and Service, 2024 data, national): CPT 96146 (automated single-instrument electronic test administration) avg Medicare allowed $2.23 office / $2.14 facility, 8,782 office services to 4,470 beneficiaries by 207 providers; CPT 99483 (cognitive assessment & care plan) avg allowed $255.96 office / $180.23 facility, 130,107 office services to 117,441 beneficiaries; CPT 96136 (test administration first 30 min) avg allowed $39.87 office; CPT 96132 (neuropsych evaluation first hour) $124.09 office. No product-specific code; vendor reimbursement claims not verified.
- What it is for
- FDA-listed Class II 510(k)-exempt Computerized Cognitive Assessment Aid (product code PTY); openFDA registration listing created 2017-11-08, valid through 2026. Tablet/phone battery (memory, attention, executive, processing speed) for cognitive impairment screening; remote self-administration studied.
- Who it was tested in
- Groppell 2019: 583 volunteers >49 y from Houston community centres/living facilities (normative n=398; SLUMS n=84, MMSE n=51, MoCA n=35, physician-diagnosis n=18). Ye 2022: 99 participants with dementia, MCI or normal cognition. 2025 remote study: 46 adults 52-76.
- Published accuracy
- 2019 composite score vs screeners: sensitivity 81%, specificity 94% (reference mostly SLUMS/MMSE/MoCA, physician-diagnosed subgroup only n=18). 2022 (n=99): >=88% sensitivity and specificity for dementia vs normal; >=77% for MCI vs normal and vs dementia; three-group MCI true-positive rate >=64%. 2025 remote vs coordinator-administered ICC 0.59-0.83 (n=46).
- Strength of evidence
- Weak-to-moderate: company-affiliated validation studies, small clinically diagnosed samples, no external multi-site validation; used as outcome measure in independent COVID cohorts (n=630) and an ED TBI feasibility study.
REGULATORY NUANCE: this product is FDA-LISTED as a 510(k)-EXEMPT Class II device (product code PTY, 21 CFR 882.1470) - it has had NO FDA premarket review and has no K-number; it is coded 'FDA-cleared' only because the schema offers no 'FDA-listed/exempt' value. Vendor phrases such as 'FDA Class II' or 'FDA-registered' refer to this listing. Regulatory: openFDA device/registrationlisting 'BRAINCHECK, INC.', proprietary name 'BrainCheck Assess', PTY exempt. Evidence: PMID 31518280 (doi 10.2196/12615, 2019, NCT03608722); PMID 35436212 (doi 10.2196/36825, 2022); PMID 40678715 (doi 10.3389/fdgth.2025.1571053, 2025); PMID 41943185 (2026 COVID cohort use).
Source: doi.org
Cognigram (Cogstate Brief Battery)
Measured
FDA-cleared
- Made by Cogstate Ltd
- Reimbursement: Generic Medicare context (measured, CMS Physician & Other Practitioners by Geography and Service, 2024 data, national): CPT 96146 (automated single-instrument electronic test administration) avg Medicare allowed $2.23 office / $2.14 facility, 8,782 office services to 4,470 beneficiaries by 207 providers; CPT 99483 (cognitive assessment & care plan) avg allowed $255.96 office / $180.23 facility, 130,107 office services to 117,441 beneficiaries; CPT 96136 (test administration first 30 min) avg allowed $39.87 office; CPT 96132 (neuropsych evaluation first hour) $124.09 office. No product-specific code; vendor reimbursement claims not verified.
- What it is for
- FDA-listed Class II 510(k)-exempt Computerized Cognitive Assessment Aid (PTY); openFDA registration listing 'Cognigram', created 2017-11-06, valid through 2026. Card-based tasks (detection, identification, one-card learning, one-back) measuring psychomotor speed, attention, learning, working memory.
- Who it was tested in
- 2023 JAD: 4,871 cognitively unimpaired adults and 184 with MCI (CDR 0.5) or dementia (CDR >0.5) due to AD, CBB-naive. 2021 Alz Dement (Mayo Clinic Study of Aging, population-based): 2,866 cognitively unimpaired and 226 MCI, subset with amyloid/tau PET.
- Published accuracy
- 2023: Learning/Working-Memory composite AUC 0.90 for CDR 0.5 and 0.97 for CDR >0.5 vs unimpaired; individual learning/working-memory measures AUC ~0.79-0.88 (CDR 0.5) and ~0.89-0.96 (CDR >0.5). 2021 population-based: AUC 0.75 for all MCI vs unimpaired, 0.93 for CU A-T- vs MCI A+T+, 0.86 for MCI without vs with AD biomarkers; conventional cut-offs gave sensitivity only 38% (MCI) and 73% (prodromal AD) - authors: 'clinical utility ... lower than expected'.
- Strength of evidence
- Moderate: large samples, but the population-based independent study shows much lower sensitivity than the enriched clinical sample; normative cut-offs flagged as unreliable.
REGULATORY NUANCE: this product is FDA-LISTED as a 510(k)-EXEMPT Class II device (product code PTY, 21 CFR 882.1470) - it has had NO FDA premarket review and has no K-number; it is coded 'FDA-cleared' only because the schema offers no 'FDA-listed/exempt' value. Vendor phrases such as 'FDA Class II' or 'FDA-registered' refer to this listing. Regulatory: openFDA device/registrationlisting 'COGSTATE LTD', PTY exempt. Evidence: PMID 38007647 (doi 10.3233/jad-230352, 2023); PMID 33650308 (doi 10.1002/alz.12219, 2021). Cogstate also supplies research-use batteries for trials (separate from the listed clinical product).
Source: doi.org
CNS Vital Signs / Cognitrax
Basis not stated
FDA-cleared
- Made by CNS Vital Signs LLC
- Reimbursement: Generic Medicare context (measured, CMS Physician & Other Practitioners by Geography and Service, 2024 data, national): CPT 96146 (automated single-instrument electronic test administration) avg Medicare allowed $2.23 office / $2.14 facility, 8,782 office services to 4,470 beneficiaries by 207 providers; CPT 99483 (cognitive assessment & care plan) avg allowed $255.96 office / $180.23 facility, 130,107 office services to 117,441 beneficiaries; CPT 96136 (test administration first 30 min) avg allowed $39.87 office; CPT 96132 (neuropsych evaluation first hour) $124.09 office. No product-specific code; vendor reimbursement claims not verified.
- What it is for
- FDA-listed Class II 510(k)-exempt Computerized Cognitive Assessment Aid (PTY); openFDA registration listing 'Cognitrax'/'CNS Vital Signs', created 2020-04-24, valid through 2026. Computerized versions of classic neuropsychological tests; marketed broadly (concussion, psychiatry, dementia).
- Who it was tested in
- 2025 Clin Neuropsychol: 73 cognitively healthy community-dwelling older adults (executive-function construct validity vs D-KEFS/WAIS-IV). Other recent studies loaded are in athletes (n=103) and TBI (n=49), not dementia.
- Published accuracy
- No dementia/MCI sensitivity, specificity or AUC located in Europe PMC search on 2026-09-22; construct validity of executive scores supported in healthy older adults (2025).
- Strength of evidence
- Weak for dementia detection specifically (no diagnostic-accuracy study in dementia loaded); general psychometric literature exists.
REGULATORY NUANCE: this product is FDA-LISTED as a 510(k)-EXEMPT Class II device (product code PTY, 21 CFR 882.1470) - it has had NO FDA premarket review and has no K-number; it is coded 'FDA-cleared' only because the schema offers no 'FDA-listed/exempt' value. Vendor phrases such as 'FDA Class II' or 'FDA-registered' refer to this listing. Regulatory: openFDA device/registrationlisting 'CNS VITAL SIGNS', PTY exempt. Evidence: PMID 38763890 (2025). Dementia-screening use is marketed; evidence we hold does not support a dementia accuracy claim.
Source: doi.org
Creyos (formerly Cambridge Brain Sciences)
Basis not stated
FDA-cleared
- Made by Cambridge Brain Sciences Inc. o/a Creyos (Toronto)
- Reimbursement: Generic Medicare context (measured, CMS Physician & Other Practitioners by Geography and Service, 2024 data, national): CPT 96146 (automated single-instrument electronic test administration) avg Medicare allowed $2.23 office / $2.14 facility, 8,782 office services to 4,470 beneficiaries by 207 providers; CPT 99483 (cognitive assessment & care plan) avg allowed $255.96 office / $180.23 facility, 130,107 office services to 117,441 beneficiaries; CPT 96136 (test administration first 30 min) avg allowed $39.87 office; CPT 96132 (neuropsych evaluation first hour) $124.09 office. No product-specific code; vendor reimbursement claims not verified.
- What it is for
- FDA-listed Class II 510(k)-exempt Computerized Cognitive Assessment Aid (PTY); openFDA registration listing 'Creyos', created 2024-02-20, valid through 2026. Web-based battery of 12 tasks; a two-task machine-learning MCI screener was described in 2026.
- Who it was tested in
- 2026 J Alzheimers Dis article describes a two-task screener for individuals on the AD continuum ('preliminary findings'); sample size and metrics not given in abstract. Feasibility as remote outcome in an acute stroke trial: only 242/791 (31%) completed Creyos (2025).
- Published accuracy
- Abstract states 'high sensitivity and specificity' for the two-task screener but gives no numbers; NOT recorded here as a measured value.
- Strength of evidence
- Weak/preliminary for dementia screening; feasibility limitations in older, functionally impaired patients.
REGULATORY NUANCE: this product is FDA-LISTED as a 510(k)-EXEMPT Class II device (product code PTY, 21 CFR 882.1470) - it has had NO FDA premarket review and has no K-number; it is coded 'FDA-cleared' only because the schema offers no 'FDA-listed/exempt' value. Vendor phrases such as 'FDA Class II' or 'FDA-registered' refer to this listing. Regulatory: openFDA device/registrationlisting 'CAMBRIDGE BRAIN SCIENCES INC. (O/A CREYOS)', PTY exempt. Evidence: PMID 41848390 (2026); PMID 40071564 (2025 stroke-trial feasibility).
Source: doi.org
Neurotrack Cognitive Assessment Battery
Basis not stated
FDA-cleared
- Made by Neurotrack Technologies, Inc.
- Reimbursement: Generic Medicare context (measured, CMS Physician & Other Practitioners by Geography and Service, 2024 data, national): CPT 96146 (automated single-instrument electronic test administration) avg Medicare allowed $2.23 office / $2.14 facility, 8,782 office services to 4,470 beneficiaries by 207 providers; CPT 99483 (cognitive assessment & care plan) avg allowed $255.96 office / $180.23 facility, 130,107 office services to 117,441 beneficiaries; CPT 96136 (test administration first 30 min) avg allowed $39.87 office; CPT 96132 (neuropsych evaluation first hour) $124.09 office. No product-specific code; vendor reimbursement claims not verified.
- What it is for
- FDA-listed Class II 510(k)-exempt Computerized Cognitive Assessment Aid (PTY); openFDA registration listing created 2020-11-23, valid through 2026.
- Published accuracy
- None located: Europe PMC search for 'Neurotrack' in abstracts (SRC:MED) returned no results on 2026-09-22.
- Strength of evidence
- No peer-reviewed diagnostic-accuracy evidence located; marketed product.
REGULATORY NUANCE: this product is FDA-LISTED as a 510(k)-EXEMPT Class II device (product code PTY, 21 CFR 882.1470) - it has had NO FDA premarket review and has no K-number; it is coded 'FDA-cleared' only because the schema offers no 'FDA-listed/exempt' value. Vendor phrases such as 'FDA Class II' or 'FDA-registered' refer to this listing. Included to document FDA listing status only. Any accuracy claims on vendor site are not evidence-backed by indexed literature found here.
Source: api.fda.gov
CognICA / Integrated Cognitive Assessment (ICA)
Measured
none
- Made by Cognetivity Neurosciences (London/Vancouver)
- What it is for
- 5-minute, language-independent, image-categorisation test with an AI model to detect cognitive impairment; used in NHS ADePT primary-care referral study. FDA status: no record found in openFDA 510k or registration listing on 2026-09-22 (vendor claims not verified here); CE status not verified.
- Who it was tested in
- 2021 Front Psychiatry: 230 participants (95 healthy, 80 MCI, 55 mild AD). 2023 ADePT: 99 GP-referred memory-clinic patients aged 55-90, tested at home or clinic.
- Published accuracy
- AUC 0.81 for MCI and 0.88 for mild AD vs healthy (2021, n=230). ADePT (2023, n=99): sensitivity 93% for dementia, 83% for MCI, specificity 80%; test-retest agreement 87.5%; ICA correlation with education years 0.17 vs 0.34 (MoCA). Abstract states generalisability 'from one population to another' but no external cohort metrics given.
- Strength of evidence
- Moderate: two company-affiliated studies with clinical-diagnosis reference; no independent external validation loaded.
Evidence: PMID 34366938 (2021); PMID 37781102 (doi 10.3389/fnagi.2023.1243316, 2023). Regulatory status recorded as 'none' because it could not be verified from FDA databases; may be CE-marked per vendor but unverified.
Source: doi.org
Altoida (digital neuro-signature, AR-based)
Measured
research-use-only
- What it is for
- 10-minute tablet augmented-reality task battery producing a 'digital neuro signature' to detect MCI and predict cognitive decline. No openFDA 510(k), De Novo or registration-listing record found on 2026-09-22 (vendor-reported Breakthrough Device designation not verified from a loaded page).
- Who it was tested in
- Altoida large cohort study (2022): Study A n=29 (MCI/AD, age 65+); Study B multicentre n=496 (213 MCI, 283 healthy controls); total 525 with FDG-PET, PiB PET, MRI. 2020 chapter describes a multi-site external validation study (AltoidaML) design only.
- Published accuracy
- DNS-br total score significantly associated with FDG-PET resilience signature, PiB ratio and grey/white matter volume; predicts cognitive impairment for 80+ subgroup; interaction with time (less decline with higher score). No AUC/sensitivity/specificity given in abstract.
- Strength of evidence
- Weak-to-moderate: company-affiliated cohort study; external validation study announced (2020) but results not located.
Evidence: PMID 36061297 (2022); PMID 32468532 (doi 10.1007/978-3-030-32622-7_14, 2020). Marketed as a prognostic digital biomarker; published abstracts show associations, not validated prognostic accuracy.
Source: doi.org
Winterlight speech analysis platform
Measured
research-use-only
- Made by Winterlight Labs (Toronto; acquired by Cambridge Cognition)
- Reimbursement: Not applicable (research).
- What it is for
- Automated acoustic and linguistic feature extraction (>500 features) from picture-description or other speech tasks as a digital biomarker of cognitive impairment; used in trials and memory-clinic research. No FDA 510(k)/De Novo/listing record found in openFDA on 2026-09-22.
- Who it was tested in
- 109 memory-clinic patients with AD, FTD, vascular cognitive impairment etc. vs healthy adults (2024, Front Neurol); analytical validation in 122 ALS patients (2023); daily speech in 16 community volunteers for depression (2023).
- Published accuracy
- Linguistic features (shorter words, fewer prepositional phrases, fewer nouns/more pronouns) correlated with MMSE, DRS, WAB and BNT across diagnoses; patients had shorter speech with more pauses vs healthy adults. No diagnostic AUC in loaded dementia abstract.
- Strength of evidence
- Weak-to-moderate for dementia: correlational evidence; no validated cut-offs or external diagnostic accuracy loaded.
PMID 38590720 (2024); PMID 38144173 (2023 ALS analytical validation); PMID 37426590 (2023). Speech biomarkers are heavily marketed for 'early detection'; indexed evidence we hold supports correlation with cognition, not screening accuracy.
Source: doi.org
MoCA Solo (self-administered digital MoCA)
Basis not stated
FDA-cleared
- Made by MoCA Test Inc. (MoCA Cognition, Quebec)
- Reimbursement: Generic Medicare context (measured, CMS Physician & Other Practitioners by Geography and Service, 2024 data, national): CPT 96146 (automated single-instrument electronic test administration) avg Medicare allowed $2.23 office / $2.14 facility, 8,782 office services to 4,470 beneficiaries by 207 providers; CPT 99483 (cognitive assessment & care plan) avg allowed $255.96 office / $180.23 facility, 130,107 office services to 117,441 beneficiaries; CPT 96136 (test administration first 30 min) avg allowed $39.87 office; CPT 96132 (neuropsych evaluation first hour) $124.09 office. No product-specific code; vendor reimbursement claims not verified.
- What it is for
- FDA-listed Class II 510(k)-exempt Computerized Cognitive Assessment Aid (PTY); openFDA registration listing 'MoCA Solo', created 2026-06-18. Self-administered digital version of the Montreal Cognitive Assessment.
- Who it was tested in
- Not located for MoCA Solo specifically. Remote MoCA formats have validation: telephone T-MoCA in 153 older Korean adults (52 normal, 51 MCI, 50 dementia) showed AUCs not significantly different from in-person K-MoCA-30 (2026, J Korean Med Sci); telehealth video MoCA in rural US veterans: inter-rater reliability r=0.88-0.98 across in-person/telehealth conditions with no significant score differences (2019, J Telemed Telecare).
- Published accuracy
- No product-specific accuracy loaded (listing is recent). Remote-administration MoCA evidence above is measured for telephone/video versions, not the self-administered product.
- Strength of evidence
- Weak for the product; moderate for the underlying remote MoCA administration literature.
REGULATORY NUANCE: this product is FDA-LISTED as a 510(k)-EXEMPT Class II device (product code PTY, 21 CFR 882.1470) - it has had NO FDA premarket review and has no K-number; it is coded 'FDA-cleared' only because the schema offers no 'FDA-listed/exempt' value. Vendor phrases such as 'FDA Class II' or 'FDA-registered' refer to this listing. Regulatory: openFDA registrationlisting 'MOCA TEST INC.', PTY exempt, 2026-06-18. Remote MoCA evidence: PMID 42708484 (doi 10.3346/jkms.2026.41.e238); PMID 29320916 (doi 10.1177/1357633x17752030).
Source: api.fda.gov
NeuroQuant (MRI volumetry) and NeuroQuant PET
Measured
FDA-cleared
- Made by Cortechs.ai (Cortechs Labs, Inc.), San Diego
- Cleared 2006-08-10
- Reimbursement: MRI volumetry is generally billed as an add-on to the MRI read; no product-specific Medicare code verified here.
- What it is for
- Automated MRI brain segmentation/volumetry with age- and sex-adjusted normative percentiles (hippocampal occupancy score etc.) to aid clinical assessment of neurodegeneration. 510(k)s: K061855 (2006-08-10, LLZ), K170981 (2017-09-07), K241098 (2024-08-22, QIH), OnQ Neuro K210831 (2021). NeuroQuant PET K261916 (2026-08-12, LLZ): regional/composite SUVR and Centiloid scoring for amyloid/FDG PET 'to support clinical interpretation of PET imaging performed for the assessment of cognitive impairment'.
- Who it was tested in
- Independent memory-clinic studies: Oslo cohort n=366 (79 SCD, 86 MCI, 201 dementia; 217 AD vs 70 non-AD) [2025, Brain Behav]; Oslo n=86 (41 non-dementia, 45 dementia) [2024]; US academic memory clinic n=181 [2025, Cogn Behav Neurol]; ADNI n=192 MCI with 3-year follow-up [2017, AJNR]. NeuroQuant PET 510(k) testing: 14 of 62 subjects from NCT00785759 (PET-only input, expert-defined putamen/accumbens ROIs).
- Published accuracy
- Hippocampal percentile alone: AUC 0.85 for dementia vs SCD and 0.60 for AD vs non-AD (n=366, 2025); NQ hippocampal volume AUC 0.80 vs visual MTA 0.69 for dementia vs non-dementia (n=86, 2024). Memory-clinic study (n=181, 2025): sensitivity 0.31-0.77 and specificity 0.68-0.91 of hippocampal volumes/occupancy for objective memory impairment; correlation with CVLT-II r=0.20-0.44 - 'should be used cautiously'. MCI-to-AD 3-year conversion (ADNI n=192, 2017): hippocampal volume AUC 0.69; combining regions did not improve (0.60-0.63). NeuroQuant PET (FDA summary, 2026): 21-29% of subjects had paired SUVR differing >0.1 from expert ROIs (95% CI upper bounds 51-58%); FDA notes 'true performance limits may be less favorable than estimated'.
- Strength of evidence
- Moderate for cross-sectional volumetric discrimination in independent clinical cohorts; weak-to-moderate as a prognostic tool (AUC ~0.69 for conversion). PET module has minimal published performance data (14 subjects in 510(k)).
Regulatory: openFDA device/510k records (applicant Cortechs Labs, Inc.): K061855, K170981, K241098, K261916, K210831; FDA AI-enabled device list rows K170981, K241098, K210831. Evidence: PMID 41024716 (doi 10.1002/brb3.70948, 2025); PMID 38600026 (doi 10.1002/brb3.3397, 2024); PMID 40309995 (doi 10.1097/wnn.0000000000000390, 2025); PMID 28057634 (doi 10.3174/ajnr.a5061, 2017); PMID 37696909 (2023 brain-age comparison, NQ volumetrics >80% sens/spec dementia vs non-dementia, n=232).
Source: accessdata.fda.gov
Neuroreader
Measured
FDA-cleared
- Made by Brainreader ApS (Horsens, Denmark)
- Cleared 2015-02-04
- What it is for
- 510(k) K140828 (LLZ): automated MRI brain volumetry with normative comparison to aid assessment of atrophy. Also FDA-listed under LLZ/LNH (openFDA registration listing, 2015-04-07).
- Who it was tested in
- ADNI n=192 MCI with 3-year follow-up (2017, AJNR, head-to-head with NeuroQuant); n=137 (40 TBI, 45 early-onset AD, 32 late-onset AD, 20 bvFTD) [2024, BMC Neurol].
- Published accuracy
- Hippocampal volume AUC 0.68 for MCI-to-AD conversion at 3 years (n=192, 2017; multivariable combinations 0.62-0.65, no improvement). 2024 diagnostic-group discrimination (TBI/EOAD/LOAD/bvFTD, n=137): AUCs 92.3-100%, sensitivity 82.2-100%, specificity 78.1-100% with leave-one-out cross-validation (internal validation only, small groups).
- Strength of evidence
- Weak-to-moderate: prognostic accuracy modest; diagnostic-group results are internal cross-validation in a small single-centre sample.
Regulatory: openFDA device/510k K140828 decision 2015-02-04 applicant Brainreader Aps. Evidence: PMID 28057634 (2017); PMID 39261753 (doi 10.1186/s12883-024-03844-4, 2024).
Source: accessdata.fda.gov
icobrain dm
Measured
FDA-cleared
- Made by icometrix NV (Leuven, Belgium)
- Cleared 2016-08-09
- What it is for
- Automated MRI volumetry (hippocampi, lobes, ventricles, white-matter hyperintensities) with normative percentiles for differential diagnosis of dementia. 510(k)s K161148 (2016-08-09), K180326 (2018-03-08), K181939 (2018-11-06), K192130 (2019-12-13), all LLZ; also CE-marked (stated in 2021 JAD paper).
- Who it was tested in
- Validation vs FreeSurfer and manual segmentation (2020, NeuroImage Clin). REMEMBER retrospective multi-centre clinical study (2021, JAD): 820 clinical T1 MRIs - 90 healthy controls, 93 SCD, 357 MCI, 280 AD dementia.
- Published accuracy
- Hippocampus Dice vs manual 0.86-0.88 (25th-75th percentile) vs FreeSurfer 0.80-0.83; temporal cortex volume AUC 0.99 AD vs controls in the 2020 development dataset. REMEMBER (n=820, real-world scans): best model HC vs AD dementia AUC 0.914, specificity 83.0%, sensitivity 86.3%; processing 15-30 min vs 9-32 h FreeSurfer; 0 vs 67 failures. No prognostic (MCI conversion) accuracy in loaded abstracts.
- Strength of evidence
- Moderate: company-affiliated validation plus a multi-centre clinical-practice study; cross-sectional diagnosis only, not progression.
Regulatory: openFDA device/510k records applicant Icometrix NV. Evidence: PMID 32193172 (doi 10.1016/j.nicl.2020.102243, 2020); PMID 34334402 (doi 10.3233/jad-210450, 2021).
Source: doi.org
icobrain aria
Measured
FDA-cleared
- Made by icometrix NV (Leuven, Belgium)
- Cleared 2024-11-07
- What it is for
- 510(k) K240712 (product code QBS, 21 CFR 892.2090, computer-assisted detection). Deep-learning software assisting radiologists in detecting and quantifying amyloid-related imaging abnormalities (ARIA-E on 2D FLAIR, ARIA-H on T2*-GRE) on two-time-point MRI of AD patients on amyloid-beta-directed antibody therapy; outputs ARIA radiographic severity per FDA prescribing-information categories. Directly relevant to lecanemab/donanemab safety monitoring.
- Who it was tested in
- Training: 475 FLAIR pairs (172 subjects, 51-85 y) and 326 T2*-GRE pairs (177 subjects) from aducanumab trials. Test set independent of training subjects: 199 MRI pairs from 199 subjects (mean age 70.4, 52.8% female, 78.9% White, 11.6% Asian, 0.5% Black), 33 scanners, >100 sites in 20 countries (~half US); extended set 1,015 FLAIR pairs/385 subjects and 449 GRE pairs/369 subjects. MRMC reader study: 16 US board-certified radiologists, 199 cases.
- Published accuracy
- (FDA 510(k) summary). Standalone case-level: ARIA-E sensitivity 0.94 (95% CI 0.90-0.98), specificity 0.67 (0.56-0.77), AUC 0.84 (0.77-0.89); ARIA-H sensitivity 0.87, specificity 0.66, AUC 0.81; ARIA-H microhemorrhage AUC 0.80; superficial siderosis sensitivity 0.67, specificity 0.95, AUC 0.82. Finding-level TPR: new microhemorrhages 66.1% with 0.9 false positives/case; siderosis 62.5%. Reader study: assisted reading superior to unassisted for all ARIA types; ARIA-E sensitivity rose from 70.9% to 86.5%, siderosis 49.7% to 59.9%; specificity stayed >80% except 76.7% for mild ARIA-H microhemorrhages. External validation: test subjects independent of training, multi-site/multi-country, but drawn from the same sponsor trial ecosystem; no peer-reviewed independent validation located in Europe PMC.
- Strength of evidence
- Moderate-to-strong for regulatory evidence (independent multi-site test set plus MRMC study); real-world post-market performance not yet published in indexed literature found here.
Source: FDA 510(k) summary K240712 loaded 2026-09-22 (accessdata cdrh_docs/pdf24/K240712.pdf); FDA AI-enabled device list row 11/07/2024 K240712 icometrix NV Radiology QBS. Predicate OsteoDetect DEN180005.
Source: accessdata.fda.gov
QyScore
Measured
FDA-cleared
- Made by Qynapse (Paris)
- Cleared 2019-12-13
- What it is for
- 510(k) K192531 (LLZ): automatic volumetry of grey/white matter, hippocampus, amygdala and white-matter hyperintensities from 3D T1/FLAIR MRI with normative comparison; CE-marked (stated in 2022 Eur Radiol paper).
- Who it was tested in
- Technical validation vs consensus of three expert neuroradiologists: 50 3D-T1 images (GM/WM/HP/AM) and 130 3D-T1+FLAIR (WMH) [2022, Eur Radiol].
- Published accuracy
- Dice/F1 lower CI bounds exceeded literature-derived reliability thresholds for GM, WM, hippocampus, amygdala and WMH; relative volume difference upper bounds below thresholds for WM, GM, HP, AM. No dementia diagnostic or prognostic accuracy loaded.
- Strength of evidence
- Weak for clinical (diagnostic) claims; moderate for segmentation agreement with experts. Company-affiliated authors.
Regulatory: openFDA device/510k K192531 decision 2019-12-13 applicant Qynapse; FDA AI-enabled device list row 12/13/2019 K192531. Evidence: PMID 34973104 (2022).
Source: doi.org
cNeuro cMRI / cNeuro cPET (PredictAD lineage)
Measured
FDA-cleared
- Made by Combinostics Oy (Tampere, Finland)
- Cleared 2018-01-08
- What it is for
- cNeuro cMRI 510(k) K171328 (2018-01-08, LLZ): automated MRI volumetry/atrophy quantification with normative comparison. cNeuro cPET K231576 (2023-09-14, KPS): quantification of amyloid/FDG PET (SUVR). (cNeuro cDAT K233908, 2024, is a DaTscan/ioflupane tool for parkinsonism and is out of scope.) Lineage: EU PredictAD decision-support tool integrating MRI, CSF and neuropsychology.
- Who it was tested in
- PredictAD tool study (2012, Dement Geriatr Cogn Disord): 140 ADNI MCI patients, 3 clinical raters classifying early AD with incremental data presentation.
- Published accuracy
- (decision-support effect, not standalone accuracy): rater classification accuracy improved from 62.6% to 70.0% with the tool (p<0.05) and dropped to 63.2% when the same data were shown on paper (n=140, ADNI, 2012). No standalone AUC for the cleared cNeuro products located. FDA 510(k) summaries (loaded 2026-09-22): cNeuro cMRI K171328 tested on 1,399 subjects (healthy, AD, FTLD, vascular dementia, MS) - Dice 0.88 hippocampus, 0.91 thalamus, 0.88 whole cortex vs manual; test-retest ICC 0.96 averaged over 133 structures; FLAIR WMH correlation 0.97 with manual labels. cNeuro cPET K231576 tested on PET from 2,275 subjects (flutemetamol, florbetapir, florbetaben, FDG) incl. ADNI robustness, test-retest, and comparison with visual-read/histopathology standard of truth from florbetaben Phase III data; correlation with predicate R 0.98-0.99; Centiloids per Klunk et al. 2015 method. Sensitivity/specificity vs standard of truth were not in the loaded lines.
- Strength of evidence
- Moderate for technical (segmentation/quantification) performance per FDA summaries with large test sets; weak for clinical diagnostic/prognostic accuracy (small ADNI reader study only).
Regulatory: openFDA device/510k records applicant Combinostics OY: K171328, K231576, K233908; FDA AI-enabled device list row 01/08/2018 K171328. Evidence: PMID 23222123 (2012).
Source: doi.org
Neurophet AQUA AD Plus / Neurophet SCALE PET
Measured
FDA-cleared
- Made by Neurophet, Inc. (Seoul)
- Cleared 2026-01-29
- What it is for
- AQUA AD Plus 510(k) K252496 (2026-01-29, QIH): automatic labelling, visualization and volumetric quantification of brain structures and lesions (T1 segmentation, FLAIR hyperintensities, edema-like FLAIR hyperintensities, GRE/SWI hypointense lesions) plus SUVR/Centiloid quantification from MR+PET, with normative percentiles - i.e., an integrated volumetry + amyloid PET + ARIA-relevant lesion package. SCALE PET K221405 (2022-08-05) and K252563 (2026-05-15, QIH): amyloid/FDG PET SUVR and Centiloid. Neurophet AQUA K220437 (2023), K242215 (2024), K261273 (2026).
- Who it was tested in
- FDA summary (AQUA AD Plus): training from ADNI, AIBL, PPMI and institutional sites (ages ~20-80+, White/Asian/Black; normal, MCI, AD, cerebrovascular, amyloid-related pathology). Validation on data separate from training: 60 T1 cases (segmentation), 136 FLAIR cases, 100 FLAIR edema cases from US/UK sites, 106 GRE/SWI cases from US sites, 30 paired MRI-PET for SUVR agreement, 176 paired MRI-amyloid PET from ADNI/AIBL for Centiloid classification.
- Published accuracy
- (FDA 510(k) summary, technical accuracy only). T1 segmentation Dice 0.83 +/- 0.04 cortical, 0.87 +/- 0.03 subcortical; FLAIR lesion Dice 0.90 +/- 0.04; edema-like FLAIR Dice 0.91 +/- 0.09; GRE/SWI lesion median F1 0.860 (95% CI 0.824-0.902); SUVR ICC >=0.993 vs cleared reference (K221405) in 7 AD-relevant regions (n=30); Centiloid >=30 amyloid-positivity kappa >=0.70 vs expert visual reads (n=176). No dementia diagnostic or prognostic accuracy claimed or reported. No peer-reviewed clinical validation located in Europe PMC.
- Strength of evidence
- Moderate for segmentation/quantification agreement (FDA-reviewed, held-out data); no clinical-outcome evidence.
Source: FDA 510(k) summary K252496 loaded 2026-09-22; K252563 summary (Dice on 64 independent subjects; SUVR ICC >=0.937 FDG, >=0.990 amyloid vs K221405 in 74 paired datasets per tracer; Centiloid binary agreement in 176 ADNI/AIBL pairs, ICC 0.996); openFDA device/510k records applicant Neurophet., Inc.; FDA AI-enabled device list rows 01/29/2026 K252496 and 05/15/2026 K252563/K261273.
Source: accessdata.fda.gov
MIM - Centiloid Scaling (MIM Neuro)
Basis not stated
FDA-cleared
- Made by MIM Software Inc. (Cleveland, OH)
- Cleared 2024-05-20
- What it is for
- 510(k) K233620 (LLZ): extends MIM neuro PET/SPECT quantification (voxel-based z-scores vs normal database, regional SUVr) with conversion of SUVr to the standardized Centiloid scale for amyloid PET with florbetapir, florbetaben and flutemetamol. Not an AI classifier; quantification support for amyloid PET reads (relevant to anti-amyloid therapy eligibility).
- Published accuracy
- Not extracted: the 510(k) summary sections loaded describe substantial equivalence to MIM - Additional Tracers (K223800) and MIM 4.0 Neuro; no sensitivity/specificity figures were present in the grep of the summary.
- Strength of evidence
- Regulatory equivalence only for this feature; the underlying Centiloid method is a published standard (Centiloid Project) but that source was not we hold.
Source: FDA 510(k) summary K233620 loaded 2026-09-22; openFDA device/510k applicant Mim Software, Inc. Included as a cleared quantification tool; no independent clinical accuracy data recorded.
Source: accessdata.fda.gov
Research model: deep learning on FDG-PET to predict final AD diagnosis (Ding et al., Radiology 2019)
Measured
research-use-only
- Made by UCSF Department of Radiology (academic)
- Reimbursement: Not applicable (research).
- What it is for
- InceptionV3 convolutional neural network trained on 18F-FDG PET to predict final clinical diagnosis (AD / MCI / neither) years before diagnosis.
- Who it was tested in
- Training/internal test: ADNI, 2,109 imaging studies from 1,002 patients (2005-2017), 90/10 split. External test: retrospective independent set of 40 studies from 40 patients (2006-2016) from the authors' institution.
- Published accuracy
- External independent test set (n=40): AUC 0.98 (95% CI 0.94-1.00) for final AD diagnosis; 82% specificity at 100% sensitivity, an average of 75.8 months before final diagnosis; outperformed radiologist readers (57% [4/7] sensitivity, 91% [30/33] specificity; P<.05). External validation: YES but very small (n=40, 7 AD cases, single institution).
- Strength of evidence
- Moderate-to-weak: strong internal performance, tiny external test set; not prospectively validated; not a product.
PMID 30398430, Radiology 2019 (published online 2018). Selected as a widely cited example of an externally tested imaging model; n and CI as stated in abstract loaded via Europe PMC 2026-09-22.
Source: doi.org
Research model: multimodal/multiscale deep neural network on MRI + FDG-PET for MCI conversion (Lu et al., Sci Rep 2018)
Measured
research-use-only
- Made by McGill University / academic (Lu, Popuri, Ding, Balachandar, Beg; ADNI)
- Reimbursement: Not applicable (research).
- What it is for
- Deep neural network combining structural MRI and FDG-PET to discriminate AD and to predict which MCI individuals convert to AD.
- Who it was tested in
- ADNI participants (exact n not stated in abstract). No external (non-ADNI) validation cohort mentioned.
- Published accuracy
- 82.4% accuracy identifying MCI converters 3 years before conversion (86.4% combined accuracy for conversion within 1-3 years); 94.23% sensitivity for probable AD; 86.3% specificity for non-demented controls. No AUC in abstract. External validation: NO.
- Strength of evidence
- Weak-to-moderate: single-dataset (ADNI) internal validation; representative of the field's main weakness.
PMID 29632364. Abstract loaded via Europe PMC 2026-09-22.
Source: doi.org
Research model: interpretable deep learning on MRI + age/sex/MMSE for AD classification with three external cohorts (Qiu et al., Brain 2020)
Measured
research-use-only
- Made by Boston University (Qiu, Kolachalama et al.; academic)
- Reimbursement: Not applicable (research). Follow-on multimodal framework (Qiu et al., Nat Commun 2022, PMID 35725739) extends to NC/MCI/AD/non-AD dementia with neuropathology comparison; abstract gives no AUC.
- What it is for
- Fully convolutional network producing voxel-level AD probability maps from MRI, fused with age, sex and MMSE in a multilayer perceptron for AD vs cognitively normal classification (cross-sectional diagnosis, not progression).
- Who it was tested in
- Trained on ADNI (n=417, clinically diagnosed AD and cognitively normal); externally validated on AIBL (n=382), Framingham Heart Study (n=102) and NACC (n=582). Compared against 11 practicing neurologists; high-risk regions compared with post-mortem histopathology.
- Published accuracy
- Mean AUC 0.996 (ADNI), 0.974 (AIBL), 0.876 (FHS), 0.954 (NACC) for the multimodal model; exceeded the neurologist team's diagnostic performance. External validation: YES, three independent cohorts - one of the few AD imaging models with genuinely external testing; note the drop to 0.876 in the community-based FHS cohort.
- Strength of evidence
- Strong for external validation of cross-sectional AD-vs-normal classification; does not address MCI progression, and AD-vs-normal is an easier task than clinically relevant differential diagnosis.
PMID 32357201. Abstract loaded via Europe PMC 2026-09-22.
Source: doi.org
Evidence synthesis: machine learning for predicting MCI progression - systematic, quantitative and critical review (Ansart et al., Med Image Anal 2021)
Measured
research-use-only
- Made by Paris Brain Institute / Inria ARAMIS (academic)
- Reimbursement: Not applicable.
- What it is for
- Field-level appraisal of automatic MCI-to-AD progression prediction studies; included here because external validation is the field's known weak point and this review quantifies methodological problems.
- Who it was tested in
- 172 articles, 234 experiments extracted; multivariate mixed-effects regression of methodological choices on reported performance.
- Published accuracy
- Cognitive variables, FDG-PET and (potentially) EEG/MEG significantly improved predictive performance; T1 MRI did NOT show a significant effect. Absence of a test set, or use of the test set for feature selection/parameter tuning, in nearly one-fourth of papers; further issues casting doubt on clinical relevance in 15% of studies; short-term predictions likely not better than predicting stability. Authors state the good performance of cognitive assessments 'questions the wide use of imaging'.
- Strength of evidence
- Strong (large systematic review with quantitative analysis). Key message for alzhub: published AUCs for progression models are frequently optimistic due to data leakage and lack of independent test sets.
PMID 33091740 (preprint doi 10.1101/2020.09.01.20185959). Abstract loaded via Europe PMC 2026-09-22.
Source: doi.org
Evidence synthesis: machine learning on neuroimaging for MCI-to-AD prediction - systematic review (Grueso & Viejo-Sobera, Alz Res Ther 2021)
Measured
research-use-only
- Made by Universitat Oberta de Catalunya (academic)
- Reimbursement: Not applicable.
- What it is for
- Systematic review (PRISMA) of ML applied to neuroimaging to predict MCI progression to AD dementia.
- Who it was tested in
- 452 studies screened, 116 included in qualitative analysis; datasets 'mainly extracted from ADNI with some exceptions'.
- Published accuracy
- Support vector machines mean accuracy 75.4%; convolutional neural networks mean accuracy 78.5%; MRI+PET combinations outperformed single modality; deep learning with multimodal/multidimensional data performed best. Predominance of a single dataset (ADNI) limits generalisability; external validation rarely performed.
- Strength of evidence
- Strong as a field summary; note the modest mean accuracies (~75-79%) versus headline AUCs in individual papers.
PMID 34583745. Abstract loaded via Europe PMC 2026-09-22.
Source: doi.org
Evidence synthesis: deep learning models for MCI-to-AD conversion, 2019-2026 systematic review (Ageing Research Reviews 2026)
Measured
research-use-only
- Made by Academic (authors not captured in loaded abstract)
- Reimbursement: Not applicable.
- What it is for
- PRISMA systematic review of deep-learning models for AD stage classification and MCI-to-AD conversion prediction, articles 2019-01-01 to 2026-02-20 (PubMed, Scopus, IEEE Xplore, Web of Science).
- Who it was tested in
- 60 included studies: 47 cross-sectional, 13 longitudinal; 42 of 60 relied on ADNI; 24 multimodal; 21 CNN-based, 4 RNN, 4 transformer.
- Published accuracy
- Longitudinal designs 'heterogeneous but promising'; multimodal models often strong for MCI tasks; authors caution that cross-study comparisons are unreliable because of heterogeneity in datasets, tasks, validation strategies and methodological quality. 'Heavy reliance on the ADNI dataset (42 studies) represents a major limitation to generalizability.'
- Strength of evidence
- Strong as the most recent field synthesis; confirms that external validation remains uncommon as of early 2026.
PMID 42727648, pubYear 2026. Abstract loaded via Europe PMC 2026-09-22 (abstract truncated at results paragraph in the loaded record).
Source: doi.org
NeuroQ 3.8 (PET/SPECT regional quantification)
Basis not stated
FDA-cleared
- Made by Syntermed, Inc. (Atlanta)
- Cleared 2018-08-16
- What it is for
- 510(k) K180077 (KPS): ROI-count quantification of brain PET/SPECT (FDG, amyloid agents, SPECT perfusion, dopamine transporter) vs asymptomatic-control database to assist examination of scans acquired for neurodegenerative processes underlying cognitive and movement disorders (AD, Lewy body dementia and others named in indications). Earlier NeuroQ clearances K041022 (2004), K072307 (2008), K130451 (2013). Not machine-learning; statistical comparison to normal database.
- Who it was tested in
- 510(k) summary cites prior in-house/clinical validation from K041022/K072307 and a basal-ganglia (DaT) validation; dementia-specific validation cohort sizes not stated in loaded summary.
- Published accuracy
- FDA summary reports for the dopamine-transporter module: sensitivity, specificity and accuracy of quantification-based dichotomized interpretations all >=90%; inter-observer reproducibility r=0.59-0.78. No FDG/amyloid dementia accuracy figures in loaded summary; no peer-reviewed dementia validation loaded.
- Strength of evidence
- Weak for dementia-specific claims from loaded sources (legacy quantification tool with long clinical use).
Source: FDA 510(k) summary K180077 loaded 2026-09-22; openFDA device/510k applicant Syntermed.
Source: accessdata.fda.gov
Wrist accelerometer (Axivity AX3) step count and incident dementia - UK Biobank (del Pozo Cruz et al., JAMA Neurol 2022)
Measured
research-use-only
- Made by UK Biobank accelerometry sub-study (device: Axivity AX3 wrist-worn triaxial accelerometer); analysis by University of Sydney/University of Southern Denmark
- Reimbursement: Not applicable.
- What it is for
- Population-level evidence linking device-measured daily steps and cadence to all-cause dementia risk; the basis for step-based prevention guidance.
- Who it was tested in
- 78,430 of 103,684 eligible UK adults aged 40-79 with valid wrist-accelerometer data (Feb 2013-Dec 2015); mean age 61.1; 96.7% White; median follow-up 6.9 years; 866 incident dementia cases (registry/hospital/primary-care/death linkage to Oct 2021).
- Published accuracy
- Optimal dose 9,826 steps/day HR 0.49 (95% CI 0.39-0.62); minimal dose 3,826 steps HR 0.75 (0.67-0.83); purposeful-cadence optimal dose 6,315 steps HR 0.43 (0.32-0.58); peak 30-min cadence 112 steps/min HR 0.38 (0.24-0.60). Not a diagnostic accuracy study; reverse causation possible.
- Strength of evidence
- Strong observational cohort (large n, device-measured exposure, linked outcomes); causal inference limited.
PMID 36066874. Abstract loaded via Europe PMC 2026-09-22.
Source: doi.org
Single accelerometer wearable (Axivity) gait analysis to differentiate dementia subtypes (Mc Ardle et al., Gait Posture 2020)
Measured
research-use-only
- Made by Newcastle University Brain and Movement Research Group (academic)
- Reimbursement: Not applicable.
- What it is for
- Lower-back accelerometer-derived spatiotemporal gait characteristics (pace, variability, rhythm, asymmetry, postural control) as differential markers for AD vs dementia with Lewy bodies vs Parkinson's disease dementia.
- Who it was tested in
- 80 people with MCI or dementia due to AD, DLB or PD performing six 10-m walks.
- Published accuracy
- Significant between-group differences in 7 of 14 gait characteristics (vs 2 for an instrumented walkway); ROC/AUC described as 'modest accuracy' for single characteristics (values not in abstract). Internal analysis only.
- Strength of evidence
- Weak-to-moderate (small single-centre feasibility).
PMID 31901765. Systematic review of wearable gait assessment in dementia found only 6 eligible studies (PMID 34886459, 2021).
Source: doi.org
Research: waist-mounted IMU multi-domain gait analysis for MCI identification (IEEE TNSRE 2026)
Measured
research-use-only
- Made by Academic (authors not captured)
- Reimbursement: Not applicable.
- What it is for
- Inertial measurement unit features across time, frequency, nonlinear and time-frequency domains during SPPB assessment, with SVM classifier and association-rule mining to screen for MCI.
- Who it was tested in
- Older adults in a field study (n not in abstract).
- Published accuracy
- Mean test AUC 0.897, accuracy 0.828 (SVM). External validation: NO.
- Strength of evidence
- Weak (single study, internal validation, n unspecified in abstract).
PMID 42378146. Included to show typical reported AUCs for wearable-gait MCI screening lack external validation.
Source: doi.org
Apple Watch consumer wearable in cognitive impairment research (myRhythmWatch; Amissa platform)
Measured
none
- Made by Apple Inc. (device); research platforms by academic groups (myRhythmWatch) and Amissa Health
- Reimbursement: Consumer purchase; not reimbursed. Generic Medicare RPM codes (measured, CMS 2024 national physician/supplier data): CPT 99453 set-up avg allowed $20.22 office (211,468 services); 99454 device supply/30 days $47.80 office (2,155,063 services, 384,004 beneficiaries); 99457 first 20 min management $48.86 office (2,586,281 services); 99458 add-on $39.08 office. These are condition-agnostic; no dementia-specific RPM benefit exists.
- What it is for
- Consumer smartwatch accelerometry/heart-rate/sleep streams repurposed for 24-hour sleep/wake rhythm and activity monitoring in older adults with and without MCI/dementia. Apple Watch itself has no FDA authorization for cognition (its ECG/AFib features are separate).
- Who it was tested in
- MyRhythmWatch feasibility (2025, JMIR): 40 adults (19 MCI, 21 no cognitive disorder), mean age 67.2, 1 week. Amissa case series (2025, J Gerontol A): 7 neurologist-diagnosed cognitively impaired participants, 6 months. Preference study (2026): 9 Black older adults/care partners rated Apple Watch SE highest on comfort/features.
- Published accuracy
- 100% provided >=3 valid days; later activity onset associated with worse delayed memory (beta=-0.28); more fragmented rhythms with worse processing speed (beta=0.40). Amissa: mean wear 11.48 h/day on 84.91% of days over 6 months; >700,000 observations. No diagnostic accuracy.
- Strength of evidence
- Weak (feasibility). Consumer wearables are marketed for 'brain health'; the evidence we hold shows only feasibility and cross-sectional correlations.
PMID 40194310 (2025); PMID 39478338 (doi 10.1093/gerona/glae250, 2025); PMID 41853222 (2026).
Source: doi.org
Wrist actigraphy (Philips Actical) total daily physical activity and incident AD - Rush Memory and Aging Project (Buchman et al., Neurology 2012)
Measured
research-use-only
- Made by Rush Alzheimer's Disease Center, Chicago (academic); device Actical, Philips Healthcare
- Reimbursement: Not applicable.
- What it is for
- Objective actigraphic measure of total daily (exercise plus non-exercise) physical activity as a predictor of incident clinical AD and cognitive decline.
- Who it was tested in
- 716 older adults without dementia in the Rush Memory and Aging Project; up to 10 days of continuous actigraphy; annual clinical examination with 19 cognitive tests; ~4-year average follow-up; 71 developed clinical AD.
- Published accuracy
- Total daily physical activity associated with incident AD, HR 0.477 (95% CI 0.273-0.832), robust to adjustment for self-reported activities, motor function, depressive symptoms, chronic conditions and APOE; associated with rate of global cognitive decline (estimate 0.033, SE 0.012, p=0.007).
- Strength of evidence
- Strong observational cohort evidence for actigraphy-measured activity as a risk marker; not a diagnostic device.
PMID 22517108 (PMCID PMC3335448). Abstract loaded via NCBI E-utilities 2026-09-22.
Source: doi.org
Actigraphy-derived sleep fragmentation and incident AD - Rush Memory and Aging Project (Lim et al., Sleep 2013)
Measured
research-use-only
- Made by Rush Alzheimer's Disease Center / Sunnybrook, University of Toronto (academic)
- Reimbursement: Not applicable.
- What it is for
- Actigraphic sleep fragmentation metric as a prospective risk marker for AD and cognitive decline.
- Who it was tested in
- 737 community-dwelling older adults without dementia; up to 10 consecutive days of actigraphy; follow-up up to 6 years (mean 3.3); 97 developed AD.
- Published accuracy
- HR 1.22 (95% CI 1.03-1.44, P=0.02) per 1 SD increase in sleep fragmentation; 90th vs 10th percentile 1.5-fold AD risk; 0.01-unit increase in fragmentation associated with 22% faster annual cognitive decline (P=0.03). Independent of total rest time, medical conditions and sleep-affecting medications.
- Strength of evidence
- Strong observational cohort evidence; wearable sleep metrics as risk markers, not diagnostics.
PMID 23814339 (PMCID PMC3669060). Abstract loaded via NCBI E-utilities 2026-09-22. Mechanistic follow-up: sleep fragmentation linked to microglial aging in the same cohorts (PMID 31844665, Sci Adv 2019).
Source: doi.org
TIHM (Technology Integrated Health Management) for dementia - NHS Test Bed IoT monitoring
Measured
none
- Made by University of Surrey with Surrey and Borders Partnership NHS Foundation Trust (NHS England Test Bed programme)
- Reimbursement: NHS-funded pilot; not applicable to Medicare. Generic Medicare RPM codes (measured, CMS 2024 national physician/supplier data): CPT 99453 set-up avg allowed $20.22 office (211,468 services); 99454 device supply/30 days $47.80 office (2,155,063 services, 384,004 beneficiaries); 99457 first 20 min management $48.86 office (2,586,281 services); 99458 add-on $39.08 office. These are condition-agnostic; no dementia-specific RPM benefit exists.
- What it is for
- Internet-of-Things home sensors plus vital-sign devices with machine-learning algorithms to detect and predict early signs of ill health, changes in routine, and agitation/irritability/aggression in people with dementia living at home; alerts monitored by a clinical team.
- Who it was tested in
- Sensor data from homes of people with dementia in the TIHM deployment (number not stated in loaded abstracts).
- Published accuracy
- (2018, PLoS One): hierarchical information-fusion approach recognised agitation and unusual activity patterns with accuracy of up to 80%. No clinical-outcome (hospitalization, crisis) results in the loaded abstracts.
- Strength of evidence
- Weak-to-moderate: algorithm-level evaluation; outcome evaluation of the NHS deployment not located in indexed abstracts we searched.
PMID 29723236 (2018); PMID 30290728 (2018 Br J Community Nurs description).
Source: doi.org
ORCATECH / CART (Collaborative Aging Research using Technology) in-home monitoring platform
Measured
research-use-only
- Made by Oregon Health & Science University ORCATECH (Kaye et al.); CART is an NIH/VA-funded multi-site initiative
- Reimbursement: Not applicable (research). Generic Medicare RPM codes (measured, CMS 2024 national physician/supplier data): CPT 99453 set-up avg allowed $20.22 office (211,468 services); 99454 device supply/30 days $47.80 office (2,155,063 services, 384,004 beneficiaries); 99457 first 20 min management $48.86 office (2,586,281 services); 99458 add-on $39.08 office. These are condition-agnostic; no dementia-specific RPM benefit exists.
- What it is for
- Unobtrusive continuous in-home assessment (passive infrared motion sensors, door contacts, computer-use monitoring, wearables, sleep mats) measuring walking speed, activity, time out of home, sleep, and social engagement to detect meaningful change and incident cognitive decline.
- Who it was tested in
- ISAAC cohort (2011): 265 elderly persons (mean age 83.3, 73% women) monitored an average of 33 months. CART (2020): 232 homes, n=301 across four cohorts (African American, Latinx, low-income, rural veterans).
- Published accuracy
- Mean in-home walking speed 61.0 cm/s; participants left home twice daily for 208 min/day; computer use on 43% of days, 76 min/day (2011). CART: mean daily computer use 160-169 min; 96-155 room transitions/day; nightly sleep 6.3-7.4 h (2020). No diagnostic accuracy for cognitive decline in loaded abstracts (2011 paper states intent to test this). ISAAC walking-speed study (Dodge et al., Neurology 2012; 93 participants living alone: 54 intact, 31 non-amnestic MCI, 8 amnestic MCI; mean follow-up 2.6 y): latent-trajectory models found naMCI participants more likely in the slow weekly walking-speed trajectory (p=0.01 vs fast, p=0.04 vs moderate) and in the highest or lowest walking-speed-variability groups - association, not diagnostic accuracy.
- Strength of evidence
- Moderate for feasibility and for association of in-home walking-speed trajectories with MCI (small n); no validated diagnostic thresholds.
PMID 21743050 (2011); PMID 33442584 (doi 10.1159/000512208, 2020). PMID 22689734 (doi 10.1212/wnl.0b013e318259e1de, 2012).
Source: doi.org
Research: in-home ADL-recognising sensors distinguishing dementia from healthy controls (Urwyler et al., Sci Rep 2017)
Measured
research-use-only
- Made by University of Bern / academic
- Reimbursement: Not applicable.
- What it is for
- Wireless unobtrusive home sensors recognising activities of daily living to quantify behavioural disorganisation in dementia.
- Who it was tested in
- 10 dementia patients and 10 healthy controls; ~9,600 person-hours of activity data.
- Published accuracy
- Discriminating accuracy for dementia vs healthy increased with observation duration, reaching 0.95 at 20 days (n=20 total; internal analysis, no external validation).
- Strength of evidence
- Weak (very small pilot).
PMID 28176828. Included as representative of the small-n evidence base behind passive-monitoring marketing claims.
Source: doi.org
Tele-Savvy Caregiver Program
Measured
none
- Made by Emory University Nell Hodgson Woodruff School of Nursing (Hepburn, Griffiths et al.); online adaptation of the Savvy Caregiver Program
- Reimbursement: Caregiver education is a GUIDE-covered service category from 2024-07-01; no direct product reimbursement.
- What it is for
- 43-day online psychoeducation programme for family caregivers of community-dwelling persons living with dementia: 7 weekly synchronous videoconference sessions (groups of 6-8) plus 36 asynchronous video lessons; aims to raise caregiver mastery and reduce distress.
- Who it was tested in
- Three-arm waitlist RCT (NCT03033875): 23 cohorts, N=261 caregivers randomized 2:2:1 to Tele-Savvy, attention control (Healthy Living), usual care; outcomes at 3, 6, 9, 12 months; trial slightly truncated due to COVID-19. Secondary analyses: 153 non-Hispanic Black and White caregivers; 137 for sleep outcomes.
- Published accuracy
- (2022, Gerontologist): statistically and clinically significant benefits with moderate-to-large effect sizes for depression, perceived stress, reaction to care-recipient behaviours and caregiver mastery; NO significant effect on caregiver burden or anxiety. Race subgroup (2024): improvements in mastery and depression seen in White but not Black caregivers. Sleep (2023): insomnia severity improved over time (p=0.050), d=0.31; PSQI d=0.13.
- Strength of evidence
- Strong (adequately powered RCT with attention control), with null results on burden/anxiety and differential benefit by race reported transparently.
PMID 33640979 (2022 RCT); PMID 29399825 (2018 protocol); PMID 37067896 (2024 race subgroup); PMID 38111602 (2023 sleep); PMID 36990041 (2023 post-hospitalization qualitative).
Source: doi.org
WHO iSupport for Dementia (online caregiver training and support)
Measured
none
- Made by World Health Organization; country adaptations (Australia - Flinders University; India; Netherlands; Portugal; Brazil; others)
- Cost: Free to end users (WHO programme); implementation costs not captured.
- Reimbursement: Not applicable.
- What it is for
- Self-help, web-based psychoeducation and skills training for family carers of people with dementia (up to 23 lessons; also hardcopy manual); country versions add facilitators, peer support and service navigation.
- Who it was tested in
- Virtual iSupport pragmatic RCT, Australia (ACTRN12622000199718; 2022-2024): 149 carers across four organizations, 12-month follow-up. Internal pilot RCT (n=84, Australia, 2022-2023); tailored vs usual Chinese iSupport pilot (n=78); India old-age-home carer training mixed-methods (n=35); India RCT protocol (target n=208, CTRI/2017/02/007876).
- Published accuracy
- (Australia 2025, Alz Dement): intervention vs usual care at 12 months - carer mental-health-related QoL +12.0 points (p<0.001); self-efficacy +14.8 to +18.5 points (p<0.001); social support +0.25 (p<0.028); reactions to behaviour -0.25; 60% lower hospital admission rate for people with dementia (p=0.045). Pilot RCT (2026): no clear evidence of effect on QoL, social support or self-efficacy at 6 months; 70% retention. India (2022, pre-post n=35): knowledge median 12 to 17; attitude 30 to 33.5.
- Strength of evidence
- Moderate: one positive pragmatic RCT (n=149, facilitator-enabled multicomponent version, not the bare self-help website), a null pilot, and pre-post studies; the unsupported self-help web version's efficacy remains less established. Multiple country RCT protocols registered; results for India RCT not located.
PMID 41023309 (2025 RCT); PMID 42634407 (2026 pilot); PMID 40761086 (2025 Chinese pilot); PMID 36368147 (2022 India); PMID 29739423 (2018 India protocol); PMID 34783660 (2021 iSupport VA protocol); PMID 38873509 (2024 iSupport-Portugal early adopters n=365, 88.4% with significant burden).
Source: doi.org
Mastery over Dementia (guided internet intervention for family caregivers)
Measured
none
- Made by VU University Amsterdam / Trimbos Institute (Blom, Pot et al.), Netherlands
- What it is for
- Guided self-help internet course (8 lessons plus booster, psychologist feedback) to reduce depressive and anxiety symptoms in family caregivers of people with dementia.
- Who it was tested in
- Pragmatic RCT (NTR-2051): 251 caregivers randomized (245 analysed; 149 intervention vs 96 minimal-intervention e-bulletins); predominantly female spouses/children; ages 26-87.
- Published accuracy
- (2015, PLoS One, intention-to-treat): lower depressive symptoms (CES-D, p=.034, effect size 0.26) and anxiety (HADS-A, p=.007, effect size 0.48) post-intervention. Adherence: 55.7% did not complete all 8 lessons (2015 acceptability paper).
- Strength of evidence
- Moderate-to-strong (RCT with small-to-moderate effects; high non-completion).
PMID 25679228 (2015 RCT); PMID 25648589 (2015 acceptability); PMID 23305463 (2013 protocol).
Source: doi.org
Partner in Balance (blended-care self-management programme)
Measured
none
- Made by Maastricht University / Alzheimer Centrum Limburg (Boots, de Vugt et al.), Netherlands
- Cost: EUR 2,027 mean 8-week intervention-plus-healthcare cost vs EUR 805 usual care (2026 Dutch analysis).
- Reimbursement: Not reimbursed; 2026 cost-consequence study advises awaiting long-term data.
- What it is for
- 8-week blended programme for caregivers of people with early-stage dementia: face-to-face coaching plus tailored web modules; aims to increase self-efficacy and prevent later burden.
- Who it was tested in
- Single-blind RCT (NTR4748): 81 caregivers of community-dwelling people with mild dementia (41 intervention, 40 waiting-list usual care). Cost-consequence analysis within waiting-list RCT n=78 (2026). Cluster-RCT with 24-month follow-up in progress (protocol 2023). Adapted for Huntington's disease (pilot n=18).
- Published accuracy
- (2018, JMIR): significant gains in self-efficacy (care management P=.002, d=0.85; service use P=.001, d=0.93), mastery (P=.001, d=0.94) and quality of life (P=.032, d=0.58); NO effect on depression, anxiety or perceived stress. Cost-consequence (2026): higher 8-week costs EUR 2,027 vs EUR 805 (p=0.013), utility 0.82 vs 0.76 (p=0.073, n.s.); authors do not recommend reimbursement yet.
- Strength of evidence
- Moderate (small RCT, proximal outcomes only; health-economic case unproven).
PMID 30006327 (2018 RCT); PMID 29258980 (2017 process evaluation); PMID 41208238 (2026 cost-consequence); PMID 37349828 (2023 cluster-RCT protocol); PMID 39512474 (2024 HD pilot).
Source: doi.org
Care Ecosystem (telephone/internet collaborative dementia care)
Measured
none
- Made by University of California San Francisco Memory and Aging Center (with University of Nebraska Medical Center)
- Reimbursement: Since 2024-07-01 the CMS GUIDE Model (8-year voluntary model) pays for care navigation, 24/7 support line, caregiver education and respite up to $2,500/year (CMS GUIDE page loaded 2026-09-22); 22 Care Ecosystem sites participate in GUIDE (JGS 2025). Exact GUIDE per-beneficiary payment rates were not captured from the loaded page.
- What it is for
- Care-team-navigator-led collaborative dementia care delivered by telephone and internet from centralized hubs, with dementia specialist team (advanced practice nurse, social worker, pharmacist); 12-month programme for person-with-dementia/caregiver dyads regardless of health-system affiliation.
- Who it was tested in
- Pragmatic single-blind RCT (NCT02213458): 780 dyads in California, Nebraska and Iowa enrolled 2015-2017 (512 intervention, 268 usual care); persons with dementia mean age 78.1, 56.3% female; English, Spanish or Cantonese speakers; Medicare/Medicaid-eligible; 571 completed 12-month survey.
- Published accuracy
- Outcomes at 12 months (intention-to-treat): quality of life (QoL-AD) improved B=0.53 (95% CI 0.25-1.30; P=.04); emergency department visits reduced B=-0.14 (95% CI -0.29 to -0.01; P=.04); caregiver depression (PHQ-9) B=-1.14 (95% CI -2.15 to -0.13; P=.03); caregiver burden (ZBI-12) B=-1.90 (95% CI -3.89 to -0.08; P=.046). End-of-life sub-study (2026): higher caregiver self-efficacy pre-death (beta 0.94, 95% CI 0.23-1.65, P=.01); satisfaction with EOL care not different (aOR 1.42, 95% CI 0.67-2.99).
- Strength of evidence
- Strong: large pragmatic RCT published in JAMA Internal Medicine 2019; effect sizes modest; open-source implementation materials; adopted at 28 health systems and 8 community organizations including 22 GUIDE participants (2025).
PMID 31566651 (2019 RCT); PMID 39763029 (doi 10.1111/jgs.19363, 2025 dissemination); PMID 40827842 (2026 EOL outcomes); PMID 41292421 (2025 implementation qualitative). CMS GUIDE: https://www.cms.gov/priorities/innovation/innovation-models/guide.
Source: doi.org
VA home-based clinical video telehealth (Home-CVT) dementia clinic
Measured
none
- Made by US Department of Veterans Affairs, New England GRECC / VA Bedford Healthcare System
- Reimbursement: VA-funded; outside Medicare fee schedule.
- What it is for
- In-home video telemedicine visits for outpatients of a VA dementia clinic and their family caregivers (follow-up management, home safety occupational-therapy evaluation).
- Who it was tested in
- 230 families invited (2020 study); 96% responded; patients in telemedicine group slightly younger (mean 79 vs 84); 10 caregivers in home-safety OT evaluation study; 24 caregivers interviewed on barriers (2022).
- Published accuracy
- (feasibility/satisfaction, not clinical outcomes): equivalent visit satisfaction between in-person and video visits; main reasons to enrol were convenience and less disruption; lack of a computer was the main reason to decline; participants demographically similar in race and education. No RCT outcomes.
- Strength of evidence
- Weak (feasibility, satisfaction, qualitative); no effect on health outcomes measured.
PMID 31431147 (2020); PMID 33520093 (2020 OT home safety); PMID 34096477 (2022 barriers/facilitators).
Source: doi.org
VA Pittsburgh Teledementia clinic (clinical video telehealth to rural CBOCs)
Measured
none
- Made by VA Pittsburgh Healthcare System
- Reimbursement: VA-funded.
- What it is for
- Geriatric dementia consultation by clinical video telehealth to rural community-based outpatient clinics lacking geriatric expertise; medication optimization for veterans with dementia.
- Who it was tested in
- 199 CVT patient encounters, 1 Jan-31 Dec 2016.
- Published accuracy
- (process outcomes, 2018): initial consults vs follow-ups had more medications added (0.731 vs 0.434 per encounter, p=0.0092), more total medication changes (1.769 vs 1.130, p=0.0078) and more 2015 Beers-criteria potentially inappropriate medications stopped (0.208 vs 0.072, p=0.0255). No patient-level clinical outcomes.
- Strength of evidence
- Weak (single-site retrospective process evaluation).
PMID 31011082 (Geriatrics 2018).
Source: doi.org
Evidence synthesis: telehealth/telemedicine interventions for people with dementia - 2026 systematic reviews and meta-analyses of RCTs
Measured
research-use-only
- Made by Academic (three independent review teams, 2026)
- Reimbursement: Medicare telehealth flexibilities and the GUIDE Model (2024-07-01) are the US payment context; not captured in detail here.
- What it is for
- Field-level summary of RCT evidence for telehealth-delivered interventions (video, device, software; cognitive training, movement programmes, caregiver support) in older adults with dementia/MCI.
- Who it was tested in
- Review A (Arch Psychiatr Nurs 2026): 12 RCTs, 822 people with dementia, 5 countries. Review B (J Telemed Telecare 2026): 12 RCTs, 21,500 participants (adults >=60 with dementia). Review C (Healthc Technol Lett 2026): 14 RCTs (search 11 Aug 2025).
- Published accuracy
- Review A: cognitive function SMD 1.00 (95% CI 0.56-1.43), executive function SMD -0.62 (-1.12 to -0.13), QoL SMD 0.72 (0.24-1.20). Review B: significant ADL improvement (Z=2.63, P<0.05, I2=1%) but NO effect on cognition, depression, caregiver burden or transfer rates; high heterogeneity (I2 81.6% cognition, 87% depression). Review C: 13 of 14 trials reported benefits; small samples noted. The conflicting pooled results between A and B (same year, overlapping question) show the evidence is heterogeneous and sensitive to inclusion criteria.
- Strength of evidence
- Mixed: RCT-level evidence exists but small trials, heterogeneous interventions, and inconsistent pooled findings; 'telehealth improves cognition' should not be stated as settled.
PMID 41956601 (doi 10.1016/j.apnu.2026.152101); PMID 42084481 (doi 10.1177/1357633x261447401); PMID 41685378 (doi 10.1049/htl2.70065); PMID 41716125 (2026 implementation barriers review, 25 papers, 14 countries).
Source: doi.org