Home › Research › Brain scans and imaging
Retinal oximetry: Metabolic imaging for diseases of the retina and brain
Stefánsson E, Olafsdottir OB, Eliasdottir TS, Vehmeijer W, Einarsdottir AB, Bek T, Torp TL, Grauslund J et al.. Progress in retinal and eye research, 2019-04-15
Topic: Brain proteins, microglia and lab models
Plain-language summary
Retinal oximetry imaging of retinal blood vessels measures oxygen saturation of hemoglobin. The imaging technology is non-invasive and reproducible with remarkably low variability on test-retest studies and in healthy cohorts. Pathophysiological principles and novel biomarkers in several retinal diseases have been discovered, as well as possible applications for systemic and brain disease. In diabetic retinopathy, retinal venous oxygen saturation is elevated and arteriovenous difference progressively reduced in advanced stages of retinopathy compared with healthy persons. This correlates with pathophysiology of diabetic retinopathy where hypoxia stimulates VEGF production. Laser treatment and vitrectomy both improve retinal oximetry values, which correlate with clinical outcome. The oximetry biomarker may allow automatic measurement of severity of diabetic retinopathy and predict its response to treatment. Central retinal vein occlusion is characterized by retinal hypoxia, which is evident in retinal oximetry. The retinal hypoxia seen on oximetry correlates with the extent of peripheral ischemia, visual acuity and thickness of macular edema. This biomarker may help diagnose and measure severity of vein occlusion and degree of retinal ischemia. Glaucomatous retinal atrophy is associated with reduced oxygen consumption resulting in reduced arteriovenous difference and higher retinal venous saturation. The oximetry findings correlate with worse visual field, thinner nerve fiber layer and smaller optic disc rim. This provides an objective biomarker for glaucomatous damage. In retinitis pigmentosa, an association exists between advanced atrophy, worse visual field and higher retinal venous oxygen saturation, lower arteriovenous difference. This biomarker may allow measurement of severity and progression of retinitis pigmentosa and other atrophic retinal diseases. Retinal oximetry offers visible light imaging of systemic and central nervous system vessels. It senses hypoxia in cardiac and pulmonary diseases. Oximetry biomarkers have been discovered in Alzheimer's disease and multiple sclerosis and oxygen levels in the retina correspond well with brain.
Cite this study APA, Vancouver, BibTeX · download .bib or .ris
APA 7th
Stefánsson, E., Olafsdottir, O. B., Eliasdottir, T. S., Vehmeijer, W., Einarsdottir, A. B., Bek, T., et al. (2019). Retinal oximetry: Metabolic imaging for diseases of the retina and brain. Progress in retinal and eye research. https://doi.org/10.1016/j.preteyeres.2019.04.001
Vancouver
Stefánsson E, Olafsdottir OB, Eliasdottir TS, Vehmeijer W, Einarsdottir AB, Bek T, et al. Retinal oximetry: Metabolic imaging for diseases of the retina and brain. Progress in retinal and eye research. 2019. doi:10.1016/j.preteyeres.2019.04.001. PMID: 30999027.
BibTeX
@article{stefansson2019-30999027,
author = {Stefánsson, E. and Olafsdottir, O. B. and Eliasdottir, T. S. and Vehmeijer, W. and Einarsdottir, A. B. and Bek, T. and Torp, T. L. and Grauslund, J. and others},
title = {{Retinal oximetry: Metabolic imaging for diseases of the retina and brain}},
journal = {Progress in retinal and eye research},
year = {2019},
doi = {10.1016/j.preteyeres.2019.04.001},
pmid = {30999027},
url = {https://doi.org/10.1016/j.preteyeres.2019.04.001}
}
Built from the record alzhub holds for this paper, not looked up. Volume, issue and page numbers are not held in the record. The record's author list ends in “et al.”, so not every author is named. Check the citation against the original before you use it.
Key findings
- In diabetic retinopathy, retinal venous oxygen saturation is elevated and arteriovenous difference progressively reduced in advanced stages of retinopathy compared with healthy persons.
- Glaucomatous retinal atrophy is associated with reduced oxygen consumption resulting in reduced arteriovenous difference and higher retinal venous saturation.
New to this subject? Start with our plain-English guide: Brain scans & tests →
Study details
- Evidence strengthLow
How this study scored 38/100
Published in a peer-reviewed journal. Scored zero for study design, sample size, effect reported, studied in people and randomized / blinded because the record does not state it. We have no data on journal's citation record, times cited, citations per year, impact for its field and year, cited by studies here, still being cited, senior author's track record, institution's track record and multicenter collaboration, so those were left out: it earned 22 of the 58 points we could judge it on, which is 38 out of 100.
| Component | Points | Why |
|---|---|---|
| Journal tier | 7 / 10 | Tier 3 — peer-reviewed journal (Progress in retinal and eye research) |
| Journal's citation record | — / 4 | No journal record from OpenAlex — left out of this score |
| Study design | 0 / 12 | No study design recorded — scores zero, not guessed (not stated in the record — scored 0) |
| Strength of evidence | 1 / 5 | Rated “low” in our summary |
| Peer-review validation | 10 / 10 | Peer-reviewed. Published as an article in a named peer-reviewed journal. |
| How recent | 2 / 5 | 2019 — within 10 year(s) of the newest study here |
| Sample size | 0 / 4 | Participant count not stated — scores zero (not stated in the record — scored 0) |
| Effect reported | 0 / 3 | No effect size reported — scores zero (not stated in the record — scored 0) |
| Studied in people | 0 / 3 | Not stated whether this was studied in people — scores zero (not stated in the record — scored 0) |
| Randomized / blinded | 0 / 2 | No randomization or blinding stated — scores zero (not stated in the record — scored 0) |
| Times cited | — / 7 | No citation count (not found in OpenAlex) — left out of this score |
| Citations per year | — / 5 | No citation count or no year — left out of this score |
| Impact for its field and year | — / 6 | No field-weighted citation impact (OpenAlex has none yet) — left out of this score |
| Cited by studies here | — / 6 | Not yet checked against this library's citation graph — left out of this score |
| Still being cited | — / 4 | No yearly citation counts — left out of this score |
| Senior author's track record | — / 4 | Senior author's record not available — left out of this score |
| Institution's track record | — / 3 | No institution listed in OpenAlex — left out of this score |
| Multicenter collaboration | — / 3 | Institutions not listed — left out of this score |
| Indexed in PubMed | 2 / 2 | Indexed in PubMed (PMID 30999027) |
| Free to read | 0 / 2 | Behind a paywall — scores zero |
| Points | 22 / 58 | Scored on 11 of 20 parts. We have no data for the rest, so they are left out: 22 of the 58 points we could judge it on is 38 out of 100. |
| Total | 38 / 100 | — |
What each of these 20 components measures, and what this score is not →
Read the original
Free copy unknown: no free-copy check has an answer for this record yet. That does not mean it is paywalled.
Related
Studies in the library that share something with this one. The line above each title says what.
Related studies in Brain scans and imaging from nearby years
Also tagged “retina”
5 studies in the library carry the topic tag “retina”; these are this study's neighbours in a fixed, alphabetical-by-hash tour of them, not the closest in content. All 5 tagged studies.