Get help now — free helplines

You can call any of these for free. You do not need a diagnosis, an appointment, or a crisis to call — questions and plain exhaustion are reasons enough.

  • Alzheimer's Association 24/7 Helpline 800-272-3900 24 hours a day, 365 days a year Free, confidential support and information for people with dementia, caregivers, families and the public. Master's-level clinicians. Also Spanish.
  • 988 Suicide & Crisis Lifeline 988 24/7 Call or text 988, or chat at 988lifeline.org. For anyone in emotional distress or a mental-health crisis, including caregivers.
  • Alzheimer's Foundation of America (AFA) Helpline 866-232-8484 9:00 am - 9:00 pm ET, seven days a week Licensed social workers providing support, info and referrals. Also text message and web chat. Text: 646-586-5283

In a medical emergency, call 911. More numbers, and what each line does, on the help page.

This page is alzhub.org's plain-English summary of a published study, not the paper itself. It is generated from the record we hold for this study, sourced and linked below — check the original for the full text and methods.

✓ Peer-reviewed alzhub usefulness score 48 out of 100. Biomarkers

Topic: Amyloid, tau and blood-test diagnosis

Introduction We compare the stability of phosphorylated tau (p-tau)217, amyloid beta (Aβ)42, Aβ40, Aβ42/40, and p-tau217/Aβ42 at different storage temperatures. Methods Ten ethylenediaminetetraacetic acid-plasma sample aliquots stored at frozen, refrigerated, and ambient temperatures were tested at various timepoints up to 30 days. The mean percent change from baseline was calculated. Results Aβ42 and Aβ40 concentrations decreased by >15% after 6 hours at ambient temperature and after 24 hours refrigerated, while p-tau217 remained stable over 72 hours with < 10% deviation from baseline at either storage temperature. The Aβ42/40 ratio remained relatively constant as each analyte concentration decreased concurrently, while the p-tau217/Aβ42 ratio deviated from baseline over time. All biomarkers were stable up to 30 days frozen. Discussion Differences in the stability of Aβ42 and p-tau217 may lead to altered p-tau217/Aβ42 ratio results if samples are not handled properly during the pre-analytical testing phase. Ideally, samples should be frozen promptly and sent to the laboratory frozen. Highlights Plasma phosphorylated tau (p-tau)217, amyloid beta (Aβ)42, Aβ40, Aβ42/40, and p-tau217/Aβ42 stability was assessed. P-tau217 was stable, but Aβ42 and Aβ40 started decreasing by 6 hours at ambient temperature. The analyte stability differences led to falsely increased p-tau217/Aβ42 ratios. Increases > 15% were seen in p-tau217/Aβ42 after 6 hours at ambient temperature or 24 hours at 4°C.

Cite this study APA, Vancouver, BibTeX · download .bib or .ris

APA 7th

Figdore, D. J., Schuder, B. J., Ashrafzadeh-Kian, S., Gronquist, T., Bornhorst, J. A., & Algeciras-Schimnich, A. (2025). Differences in Alzheimer's disease blood biomarker stability: Implications for the use of tau/amyloid ratios. Alzheimer's & dementia : the journal of the Alzheimer's Association. https://doi.org/10.1002/alz.70173

Vancouver

Figdore DJ, Schuder BJ, Ashrafzadeh-Kian S, Gronquist T, Bornhorst JA, Algeciras-Schimnich A. Differences in Alzheimer's disease blood biomarker stability: Implications for the use of tau/amyloid ratios. Alzheimer's & dementia : the journal of the Alzheimer's Association. 2025. doi:10.1002/alz.70173. PMID: 40308118.

BibTeX

@article{figdore2025-40308118,
  author  = {Figdore, D. J. and Schuder, B. J. and Ashrafzadeh-Kian, S. and Gronquist, T. and Bornhorst, J. A. and Algeciras-Schimnich, A.},
  title   = {{Differences in Alzheimer's disease blood biomarker stability: Implications for the use of tau/amyloid ratios}},
  journal = {Alzheimer's \& dementia : the journal of the Alzheimer's Association},
  year    = {2025},
  doi     = {10.1002/alz.70173},
  pmid    = {40308118},
  url     = {https://doi.org/10.1002/alz.70173}
}

Built from the record alzhub holds for this paper, not looked up. Volume, issue and page numbers are not held in the record. Check the citation against the original before you use it.

Key findings

Study details

How this study scored 48/100
How this study's score is builtJournal tier 9 of 10; Journal's citation record left out, no data; Study design 0 of 12; Strength of evidence 1 of 5; Peer-review validation 10 of 10; How recent 4 of 5; Sample size 0 of 4; Effect reported 0 of 3; Studied in people 0 of 3; Randomised / blinded 0 of 2; Times cited left out, no data; Citations per year left out, no data; Impact for its field and year left out, no data; Cited by studies here left out, no data; Still being cited left out, no data; Senior author's track record left out, no data; Institution's track record left out, no data; Multi-centre collaboration left out, no data; Indexed in PubMed 2 of 2; Free to read 2 of 2. 28 of the 58 points it could be judged on, which is 48 of 100. Total 48 of 100.28 of the 58 points we could judge = 48 of 100

Published in a leading specialty journal. Scored zero for study design, sample size, effect reported, studied in people and randomised / blinded because the record does not state it. We have no data on journal's citation record, times cited, citations per year, impact for its field and year, cited by studies here, still being cited, senior author's track record, institution's track record and multi-centre collaboration, so those were left out: it earned 28 of the 58 points we could judge it on, which is 48 out of 100.

ComponentPointsWhy
Journal tier 9 / 10 Tier 2 — leading specialty journal (Alzheimer's & dementia : the journal of the Alzheimer's Association)
Journal's citation record — / 4 No journal record from OpenAlex — left out of this score
Study design 0 / 12 No study design recorded — scores zero, not guessed (not stated in the record — scored 0)
Strength of evidence 1 / 5 Rated “low” in our summary
Peer-review validation 10 / 10 Peer-reviewed. Published as an article in a named peer-reviewed journal.
How recent 4 / 5 2025 — within 3 year(s) of the newest study here
Sample size 0 / 4 Participant count not stated — scores zero (not stated in the record — scored 0)
Effect reported 0 / 3 No effect size reported — scores zero (not stated in the record — scored 0)
Studied in people 0 / 3 Not stated whether this was studied in people — scores zero (not stated in the record — scored 0)
Randomised / blinded 0 / 2 No randomisation or blinding stated — scores zero (not stated in the record — scored 0)
Times cited — / 7 No citation count (not found in OpenAlex) — left out of this score
Citations per year — / 5 No citation count or no year — left out of this score
Impact for its field and year — / 6 No field-weighted citation impact (OpenAlex has none yet) — left out of this score
Cited by studies here — / 6 Not yet checked against this library's citation graph — left out of this score
Still being cited — / 4 No yearly citation counts — left out of this score
Senior author's track record — / 4 Senior author's record not available — left out of this score
Institution's track record — / 3 No institution listed in OpenAlex — left out of this score
Multi-centre collaboration — / 3 Institutions not listed — left out of this score
Indexed in PubMed 2 / 2 Indexed in PubMed (PMID 40308118)
Free to read 2 / 2 Free to read
Points 28 / 58 Scored on 11 of 20 parts. We have no data for the rest, so they are left out: 28 of the 58 points we could judge it on is 48 out of 100.
Total 48 / 100 —

What each of these 20 components measures, and what this score is not →

Read the original

Free copy unknown: no free-copy check has an answer for this record yet. That does not mean it is paywalled.

Related studies in Biomarkers

Also tagged “blood-biomarkers”

2 studies in the library carry the topic tag “blood-biomarkers”; these are this study's neighbours in a fixed, alphabetical-by-hash tour of them, not the closest in content. All 2 tagged studies.

Similar studies

More on Biomarkers

See all studies in Biomarkers →