Home › Research › What the research found › Every row
Every row of the evidence table
One row per finding: what was tested, which way the result went, and how the study was built. The answer by area, and where the studies disagree, are on the main page.
Every row
Filter
Showing 3 of 382 rows for Cognitive screening instrument accuracy. One row per study per exposure: a study that tested two different things appears twice, once for each.
Scroll the table sideways to see every column.
| Exposure | Question | Direction | Outcome measured | Design | People | Effect size, as the source reported it | Source |
|---|---|---|---|---|---|---|---|
| Cognitive screening instrument accuracy Care, carers and services | Treatment |
Benefit
whyDirection is for the test's accuracy against the reference standard; an accuracy result, not a health outcome. Tablet tests correlated strongly with MMSE, MoCA and Trails A (r > 0.7) and the Match test separated amyloid-positive from -negative patients (AUC 0.82) better than MMSE or MoCA (0.75). |
Correlation with pen-and-paper tests and discrimination of amyloid-positive from amyloid-negative early-onset AD patients | cross-sectional study | 475 | Match and Flanker were associated with all pen‐and‐paper tests, with strongest correlations observed with the MMSE, MoCA, and Trails A (r's >0.7) ... Of TabCAT tests, Match best discriminated Aβ+ from Aβ‐ patients (Area Under the Curve (AUC)=0.82), outperforming the MMSE (AUC=0.75) and MoCA (AUC=0.75), and comparable to the overall best performing test Benson Figure Recall (AUC=0.85 |
Alzheimer's & Dementia (AAIC 2025 conference abstract)
2025 ⚠ Conference abstract — not peer-reviewed DOI 10.1002/alz70857_104654 |
| Cognitive screening instrument accuracy Care, carers and services | Treatment |
Benefit
whyDirection is for the test's accuracy against the reference standard; an accuracy result, not a health outcome. Pooled sensitivity 76% and specificity 83% for dementia, with 73% / 84% in primary care; the authors call it a practical screening tool while noting high or unclear risk of bias in patient selection and timing. |
Pooled sensitivity and specificity of the Mini-Cog for dementia, MCI and cognitive impairment | meta-analysis | not stated | To detect dementia (six studies, n = 4772), the Mini-Cog showed 76% sensitivity and 83% specificity. To detect MCI (two studies, n = 270), it showed 84% sensitivity and 79% specificity. To detect CI (eight studies, n = 2152), it had 67% sensitivity and 83% specificity. In the primary care setting, to detect either MCI, dementia, or CI (eight studies, n = 5620), the Mini-Cog demonstrated 73% sensitivity and 84% specificity |
PLOS ONE
2024 ✓ Peer-reviewed PMID 38483857 |
| Cognitive screening instrument accuracy Care, carers and services | Treatment |
Benefit
whyDirection is for the test's accuracy against the reference standard; an accuracy result, not a health outcome. The two-stage GPCOG had sensitivity 0.85 and specificity 0.86 against DSM-IV dementia, and was superior to the Abbreviated Mental Test. |
Sensitivity, specificity and positive predictive value of the GPCOG for dementia in general practice | cross-sectional study | 283 | The two-stage method of administering the GPCOG (cognitive testing followed by informant questions if necessary)had a sensitivity of 0.85, a specificity of 0.86, a misclassification rate of 14%, and positive predictive value of 71.4% |
Journal of the American Geriatrics Society
2002 ✓ Peer-reviewed PMID 11943052 |